Low-smoke halogen-free wire and cable
This product is suitable for transmission of electric energy in power lines with a rated voltage of 0.6/1KV and below. LSZH cables can be divided into LSZH series and LSZH series. Low-smoke, halogen-free, flame-retardant cables are difficult to catch fire and have the ability to prevent or delay the spread of flames. Moreover, once a fire occurs, it has the characteristics of halogen-free, low-smoke, non-toxic, and non-corrosive. It is suitable for high-rise buildings, hotels, hospitals, etc. , Subways, nuclear power plants, tunnels, power plants, mines, petroleum, chemical industries, etc. In addition to meeting the characteristics of low-smoke, halogen-free and flame-retardant cables, low-smoke halogen-free fire-resistant cables can also meet line power supply capabilities under fire conditions. Mainly used in fire alarm, fire fighting equipment, smoke exhaust equipment, emergency channel transportation, lighting and other emergency facilities in the power supply line where fire resistance is required.
Classification:
Key words:
Low-smoke halogen-free wire and cable
- Description
- Model and specification
- Usage characteristics
- Parameter
- Transportation
-
- Commodity name: Low-smoke halogen-free wire and cable
- Commodity ID: 1329827699333156864
This product is suitable for transmission of electric energy in power lines with a rated voltage of 0.6/1KV and below. LSZH cables can be divided into LSZH series and LSZH series. Low-smoke, halogen-free, flame-retardant cables are difficult to catch fire and have the ability to prevent or delay the spread of flames. Moreover, once a fire occurs, it has the characteristics of halogen-free, low-smoke, non-toxic, and non-corrosive. It is suitable for high-rise buildings, hotels, hospitals, etc. , Subways, nuclear power plants, tunnels, power plants, mines, petroleum, chemical industries, etc. In addition to meeting the characteristics of low-smoke, halogen-free and flame-retardant cables, low-smoke halogen-free fire-resistant cables can also meet line power supply capabilities under fire conditions. Mainly used in fire alarm, fire fighting equipment, smoke exhaust equipment, emergency channel transportation, lighting and other emergency facilities in the power supply line where fire resistance is required.
This product is suitable for power transmission in power lines with a rated voltage of 0.6/1KV and below use.
Product implementation standards: GB/t19666-2005, GB/T12706.1-2008, GB/T9330-2008Instructions for low-smoke and halogen-free cables
LSZH cables can be divided into LSZH series and LSZH series.
Low-smoke halogen-free cables are produced by our company in accordance with French standards RCCE and NF series standards, national standards GB/T18380, GB/T19216, GB/T17651, GB/T17650 and international standards.
The low-smoke, halogen-free, flame-retardant cable is difficult to catch fire and has the ability to prevent or delay the spread of flames. Moreover, once it catches fire, it has the characteristics of halogen-free, low-smoke, non-toxic, non-corrosive, etc., suitable for high-rise buildings, hotels, hospitals, etc. , Subways, nuclear power plants, tunnels, power plants, mines, petroleum, chemical industries, etc.
In addition to meeting the characteristics of low-smoke, halogen-free and flame-retardant cables, low-smoke halogen-free fire-resistant cables can also meet line power supply capabilities under fire conditions. Mainly used in fire alarm, fire fighting equipment, smoke exhaust equipment, emergency channel transportation, lighting and other emergency facilities in the power supply line where fire resistance is required.
Flame retardant grades of low-smoke and halogen-free cables
According to the test conditions specified in GB/T18380.3-2008, the flame retardant grades of low-smoke halogen-free cables are divided into four grades: A, B, C, and D. If the flame retardant grade is not indicated, it will be regarded as B grade.Flame retardant grade
Fire temperature
Fire supply time
The volume of non-metallic materials for laying cables in bundles
Charring height
Self-extinguishing time
A
≥815℃
40min
≥7L/m
≤2.5m
≤1h
B
≥815℃
40min
≥3.5L/m
≤2.5m
≤1h
C
≥815℃
20min
≥1.5L/m
≤2.5m
≤1h
D
≥815℃
20min
≥0.5L/m
≤2.5m
≤1h
Product structure:
-
Representation of low-smoke and halogen-free cable products
The model of the low-smoke halogen-free cable consists of two parts: the combustion characteristic code and the cable modelCode of combustion characteristics
Name
Code name
Flame retardant Class A
ZA
Flame retardant grade B
ZB
Flame retardant C grade
ZC
Flame retardant Class D
ZD
Refractory
N
Halogen-free and low-smoke
WD
Usage code
Name
Codename
Electricity
Omitted
Control
K
Wiring
B
Material code
Name
Codename
Copper conductor
Omit
Cross-linked polyethylene insulation
YJ
Polyolefin sheath
Y(E)
Products are represented by model, rated voltage, core number, nominal cross-section and the number of this standard
For example:
Rated voltage 600/1000V XLPE insulated polyolefin sheathed flame-retardant type B low-smoke halogen-free cable, 3-core, 240mm2, denoted as WDZB-YJY 600/1000V 3*240 Q/ TEC16. 05-2005
Rated voltage 600/1000V XLPE insulated polyolefin sheathed flame-retardant Class B fire-resistant low-smoke halogen-free cable, 3-core, 240mm2, denoted as WDZBN-YJY 600/1000V ; 3*240 Q/TEC16. 05-2005
Rated voltage 450/750V XLPE insulated polyolefin sheathed flame-retardant type B low-smoke halogen-free control cable, 7 cores, 1.5mm2, denoted as WDZB-KYJY 450/750V 7*1.5 ;. Q / TEC16 05-2005The model and name of the cable
Model
Name
Flame retardant rating
Core number
Cross section
mm2Rated voltage
vWDZ-KYJY
(WDZ-KYJE)Crosslinked polyethylene insulated low smoke and halogen free frame retardant control cable with polyolefin sheath
A, B, C, D
2-61
1-10
450/750
WDZ-KYJY22
(WDZ-KYJE22)Crosslinked polyethylene insulated low smoke and halogen free flame retardant control cable with polyolefin sheath and copper tape armoring
A, B, C, D
2-61
1-10
450/750
WDZ-KYJYP2 (WDZ-KYJEP2)
Crosslinked polyethylene insulated low smoke and halogen free flame retardant control cable with polyolefin sheath and copper tape shielding
A, B, C, D
2-61
1-10
450/750
WDZ-KYJYP2-22
(WDZ-KYJEP2-22)Crosslinked polyethylene insulated low smoke and halogen free flame retardant control cable with polyolefin sheath, copper tape shielding arm arm p>
A, B, C, D
2-61
1-10
450/750
WDZN-KYJY
(WDZN-KYJE)Crosslinked polyethylene insulated low smoke and halogen free flame resistant control cable with polyolefin sheath and steel tape armoring
A, B, C, D
2-61
1-10
450/750
WDZN-KYJY22
(WDZN-KYJE22)Crosslinked polyethylene insulated low smoke and halogen free flame retardant fire resistant control cable with polyolefin and steel tape arm
A, B, C, D
2-61
1-10
450/750
WDZN-KYJYP2
(WDZN-KYJEP2)Crosslinked polyethylene insulated low smoke and halogen free flame retardant fire resistant control cable with polyolefin sheath and polyolefin
A, B, C, D
2-61
1-10
450/750
WDZN-KYJYP2-22
(WDZN-KYJEP2-22)Crosslinked polyethylene insulated low smoke and halogen free flame retardant fire resistant control cable with polyolefin sheath, copper tape tape tape ;armoring
A, B, C, D
2-61
1-10
450/750
WDZ-YJY
(WDZ-YJE)Cross-linked polyethylene insulated polyolefin sheathed low-smoke halogen-free power cable
Crosslinked polyethylene insulated low smoke and halogen free flame retardant power cable with polyolefin sheathA, B, C, D
1-5
1.5-800
600/1000
WDZ-YJY22
(WDZ-YJE22)Crosslinked polyethylene insulated low smoke and halogen free flame retardant power cable with polyolefin sheath and steel arm
A, B, C, D
1-5
1.5-400
600/1000
WDZN-YJY
(WDZN-YJE)Crosslinked polyethylene insulated low smoke and halogen free flame retardantfire retardant power cable with polyolefin sheath
A, B, C, D
1-5
1.5-800
600/1000
WDZN-YJY22
(WDZN-YJE22)Crosslinked polyethylene insulated low smoke and halogen free flame retardant fire retardant power cable with polyolefin sheath and steel arm steel
A, B, C, D
1-5
1.5-400
600/1000
-
Using features
The rated voltage U0/U of the power cable is 0.6/1KV, and the rated voltage U0/U of the control cable is 450/750V.
The long-term allowable working temperature of the cable does not exceed 90℃
The ambient temperature during installation should not be lower than 0°C.
Minimum bending radius during cable installation:
Low-smoke, halogen-free, flame-retardant and fire-resistant control cables: cables with no armor layer should be no less than 6 times the outer diameter of the cable, and cables with armor or copper tape shielding structure should be no less than 12 times the outer diameter of the cable.
The minimum bending radius of low-smoke, halogen-free, flame-retardant and fire-resistant power cables is shown in Table 3Project
Single core cable
Multi-core cable
Unarmored
Armored
Unarmored
Armored
Minimum bending radius during installation
20D
15D
15D
12D
D-Outer diameter of the cable
For the nominal cross section of the neutral conductor of the multi-core cable, see Table 4 ; ; ; ; ; ;Table 4 Nominal cross-section of neutral conductor of multi-core cable
Nominal cross section of main insulated core conductor
Nominal cross section of main insulated core conductor /min2Nominal cross section of neutral conductor
Nominal cross section of neutral conductor /min23+1, 3+2, 4+1 Cores
4, 5 Cores
4
2.5
4
6
4
6
10
6
10
16
10
16
25
16
25
35
16
35
50
25
50
70
35
70
95
50
95
120
70
120
150
70
150
185
95
185
240
120
240
300
150
300
400
185
400
Single-core cable conductive core is round, 16mm2 and above can be pressed tightly. For multi-core cables with a cross-section of 35mm2 and below, the core should be round, and those with a cross-section of 50mm2 and above should be fan-shaped, tile-shaped or semicircular. The fourth core (neutral core) in a four-core cable can be round or fan-shaped. The neutral wire of a five-core cable can be round or tile-shaped. Those with a diameter of 6mm2 and below are allowed to be composed of a single conductor, and those with a diameter of 10mm2 and above are composed of multiple single wires. The shaped conductor (sector, tile or semicircle) should be tightly pressed.
Main performance:
Low-smoke halogen-free flame retardant type
The flame retardant performance should be able to pass the GB18380 bundled cable burning test. After the test, the height of the cable scorch or the affected part should not exceed 2.5m above the point of action of the flame. Or a single vertical burning test.
The halogen acid gas release test should be able to pass the determination of the total amount of halogen acid gas in GB/T17650.1-1998∠5mg/g and GB/T17650.2-19981 measure the acidity of the gas by measuring the PH value and conductivity (PH≥4.3 conductivity in 1L water should not exceed 10us/mm)
The smoke density test should be able to pass the determination of the smoke density of GB/T17651.2-1998 cable or optical cable burning under specific conditions (minimum light transmittance ≥ 60%)
Conductor DC resistance meets the requirements of GB/T3956
Power frequency withstand voltage test: The power cable should withstand 3500V for 5min without breakdown. The control cable should withstand 3000V without breakdown for 5 minutes.
Should withstand the low temperature winding test or low temperature impact test at -15℃. After the test, there should be no visible cracks on the surface of the sample.
Low-smoke halogen-free refractory type
In addition to meeting the performance of flame-retardant, low-smoke and halogen-free type, its fire resistance test should be able to pass the requirements of GB/T19216-2003 under flame conditions or line integrity test of optical cable. Burn at 750℃ for 90min, 2A fuse will not blow . -
Cable specifications and reference dataSee table5-12
Table5 Copper core radiation cross-linked polyethylene insulation, low smoke and no Halogen flame retardant wire and cable structure parameters
sectionmm2
Structure
Theoretical outer diametermm
Theoretical weightkg/km
20℃When the conductor resistance is not greater than Ω/km
Number of roots/diameter
Insulation thicknessmm
WDZ-BYJ(F)
WDN-BYJ(F)
WDZ-BYJ(F)
WDN-BYJ(F)
1*1.0
1/1.13
0.6
2.3
3.0
14.8
19.5
18.1
1*1.0
7/0.43
0.6
2.5
3.1
15.4
20.3
18.1
1*1.5
1/1.38
0.7
2.8
3.4
21.6
27.1
12.1
1*1.5
7/0.52
0.7
3.0
3.6
22.4
28.2
12.1
1*2.5
1/1.78
0.8
3.4
4.0
33.9
40.5
7.41
1*2.5
7/0.68
0.8
3.6
4.3
35.3
42.3
7.41
1*4
1/2.25
0.8
3.9
4.5
49.3
56.7
4.61
1*4
7/0.85
0.8
4.2
4.8
51.1
59.0
4.61
1*6
1/2.76
0.8
4.4
5.0
69.4
77.7
3.08
1*6
7/1.04
0.8
4.7
5.4
71.6
80.5
3.08
1*10
7/1.35
1
6.1
6.7
118.3
129.6
1.83
1*16
7/1.7
1
7.2
7.8
178.6
191.8
1.15
1*25
7/2.14
1.2
8.8
9.5
276.2
292.3
0.727
1*35
7/2.52
1.2
10.0
10.6
373.7
391.8
0.524
1*50
19/1.78
1.4
11.7
12.3
530.5
551.7
0.387
1*70
19/2.14
1.4
13.5
14.1
724.3
748.7
0.268
1*95
19/2.52
1.6
15.8
16.4
981.5
1009.9
0.193
1*120
37/2.03
1.6
17.4
18.1
1220.5
1251.7
0.153
1*150
37/2.25
1.8
19.4
20.0
1525.5
1560.1
0.124
1*185
37/2.52
2
21.6
22.3
1883.2
1921.9
0.0991
1*240
61/2.25
2.2
24.7
25.3
2434.3
2478.2
0.0754
1*300
61/2.52
2.4
27.5
28.1
3034.1
3083.0
0.0601
1*400
61/2.89
2.6
31.2
31.9
4012.3
4067.8
0.0470
Table 6 Structural parameters of soft copper core irradiated cross-linked polyethylene insulated low-smoke halogen-free flame-retardant wire and cable
section
mm²
structure Theoretical outer diameter mm
Theoretical weight kg/km
Conductor resistance at 20℃ is not greater than Ω/km
Root number/diameter Insulation thickness WDZ-BYJ(F)
WDN-BYJ(F)
WDZ-BYJ(F)
WDN-BYJ(F)
1
7/0.43
0.6
2.7
3.2
18.1
22.5
18.1
1.5
7/0.52
0.6
2.9
3.5
22.9
28.1
12.1
2.5
19/0.41
0.6
3.4
4.0
34.6
40.6
7.41
4
19/0.52
0.7
4.2
4.6
53.9
58.4
4.61
6
19/0.64
0.7
4.8
5.4
76.2
84.6
3.08
10
49/0.52
0.9
6.8
7.0
130.0
133.0
1.83
16
49/0.64
0.9
7.9
8.5
195.3
208.6
1.15
25
98/0.58
1.0
9.6
9.9
297.3
307.3
0.727
35
133/0.58
1.0
11.2
11.8
406.0
424.7
0.524
50
133/0.68
1.2
13.2
13.4
578.9
584.7
0.387
70
189/0.68
1.2
15.7
16.3
793.9
819.8
0.268
Table 7 WDZ-KYJ(F)Y Irradiation cross-linked polyethylene insulated polyolefin sheathed low-smoke halogen-free flame-retardant control cable
Number of cores * section
mm²
structure Outer diameter mm Theoretical weight kg/km Number of cores * section mm² structure Outer diameter mm Theoretical weight kg/km Number of cores * section mm²
structure Outer diameter mm Theoretical weight kg/km 2*1.5
1/1.38
8.4
106
7*1.5
1/1.38
11.1
233
14*1.5
1/1.38
15.7
443
2*1.5
7/0.52
8.7
116
7*1.5
7/0.52
11.7
244
14*1.5
7/0.52
16.5
463
2*2.5
1/1.78
9.2
139
7*2.5
1/1.78
12.9
338
14*2.5
1/1.78
17.4
607
2*2.5
7/0.68
9.7
146
7*2.5
7/0.68
13.7
360
14*2.5
7/0.68
18.6
636
2*4
1/2.25
10.1
177
7*4.0
1/2.25
14.4
459
14*4.0
1/2.25
19.9
863
2*4
7/0.85
10.7
189
7*4.0
7/0.85
15.3
479
14*4.0
7/0.85
21.2
899
2*6
1/2.76
11.1
229
7*6.0
1/2.76
15.9
613
14*6.0
1/2.76
22.2
1165
2*6
7/1.04
11.8
248
7*6.0
7/1.04
17.0
638
14*6.0
7/1.04
23.8
1210
3*1.5
1/1.38
8.8
135
8*1.5
1/1.38
12.6
285
16*1.5
1/1.38
16.5
494
3*1.5
7/0.52
9.2
140
8*1.5
7/0.52
13.2
298
16*1.5
7/0.52
17.3
516
3*2.5
1/1.78
9.6
176
8*2.5
1/1.78
13.9
382
16*2.5
1/1.78
18.7
701
3*2.5
7/0.68
10.2
185
8*2.5
7/0.68
14.8
401
16*2.5
7/0.68
20.0
734
3*4
1/2.25
10.7
230
8*4.0
1/2.25
15.4
520
19*1.5
1/1.38
17.3
566
3*4
7/0.85
11.3
242
8*4.0
7/0.85
16.4
542
19*1.5
7/0.52
18.2
591
3*6.0
1/2.76
12.4
328
8*6.0
1/2.76
17.5
715
19*2.5
1/1.78
19.7
807
3*6.0
7/1.04
13.1
342
8*6.0
7/1.04
18.7
746
19*2.5
7/0.68
21.0
845
4*1.5
1/1.38
9.5
164
10*1.5
1/1.38
14.5
350
24*1.5
1/1.38
20.5
724
4*1.5
7/0.52
9.9
171
10*1.5
7/0.52
15.2
365
24*1.5
7/0.52
21.6
757
4*2.5
1/1.78
10.5
217
10*2.5
1/1.78
16.1
470
24*2.5
1/1.78
22.9
1002
4*2.5
7/0.68
11.1
228
10*2.5
7/0.68
17.2
495
24*2.5
7/0.68
24.4
1049
4*4.0
1/2.25
12.2
311
10*4.
1/2.25
18.4
663
27*1.5
1/1.38
20.9
793
4*4.0
7/0.85
12.9
324
10*4.0
7/0.85
19.6
692
27*1.5
7/0.52
22.0
828
4*6.0
1/2.76
13.4
411
10*6.0
1/2.76
20.4
884
27*2.5
1/1.78
23.4
1103
4*6.0
7/1.04
14.3
428
10*6.0
7/1.04
21.9
925
27*2.5
7/0.68
25.0
1154
5*1.5
1/1.38
10.3
175
12*1.5
1/1.38
14.9
393
30*1.5
1/1.38
21.6
865
5*1.5
7/0.52
10.8
183
12*1.5
7/0.52
15.7
410
30*1.5
7/0.52
22.8
903
5*2.5
1/1.78
12.0
260
12*2.5
1/1.78
16.6
535
30*2.5
1/1.78
24.2
1207
5*2.5
7/0.68
12.7
272
12*2.5
7/0.68
17.7
561
30*2.5
7/0.68
25.9
1263
5*4.0
1/2.25
13.3
349
12*4.0
1/2.25
19.0
758
37*1.5
1/1.38
23.3
1033
5*4.0
7/0.85
14.1
363
12*4.0
7/0.85
20.2
791
37*1.5
7/0.52
24.5
1078
5*6.0
1/2.76
14.6
463
12*6.0
1/2.76
21.1
1019
37*2.5
1/1.78
26.1
1451
5*6.0
7/1.04
15.6
480
12*6.0
7/1.04
22.6
1060
37*2.5
7/0.68
27.9
1517
Table 8 WDZN-KYJ(F)Y Irradiation cross-linked polyethylene insulated polyolefin sheathed low-smoke halogen-free flame-retardant fire-resistant power control cable
Number of cores*Section mm² structure Outer diameter mm Theoretical weight kg/km
Number of cores*Section mm² structure
Outer diameter mm Theoretical weight kg/km
Number of cores*Section mm² structure
Outer diameter mm Theoretical weight kg/km
2*1.5
1/1.38
10.0
165
7*1.5
1/1.38
13.5
284
14*1.5
1/1.38
18.9
542
2*1.5
7/0.52
10.4
186
7*1.5
7/0.52
14.0
297
14*1.5
7/0.52
19.7
566
2*2.5
1/1.78
10.8
210
7*2.5
1/1.78
15.3
397
14*2.5
1/1.78
20.7
715
2*2.5
7/0.68
11.4
217
7*2.5
7/0.68
16.0
422
14*2.5
7/0.68
21.8
750
2*4
1/2.25
11.8
249
7*4.0
1/2.25
16.7
523
14*4.0
1/2.25
23.1
985
2*4
7/0.85
12.4
258
7*4.0
7/0.85
17.6
546
14*4.0
7/0.85
24.5
1028
2*6
1/2.76
12.8
299
7*6.0
1/2.76
18.2
682
14*6.0
1/2.76
25.4
1298
2*6
7/1.04
13.5
310
7*6.0
7/1.04
19.3
711
14*6.0
7/1.04
27.0
1332
3*1.5
1/1.38
10.6
196
8*1.5
1/1.38
15.1
355
16*1.5
1/1.38
19.9
605
3*1.5
7/0.52
11.0
203
8*1.5
7/0.52
15.7
370
16*1.5
7/0.52
20.7
631
3*2.5
1/1.78
11.4
248
8*2.5
1/1.78
16.4
457
16*2.5
1/1.78
22.2
826
3*2.5
7/0.68
12.0
258
8*2.5
7/0.68
17.3
479
16*2.5
7/0.68
23.4
866
3*4
1/2.25
12.4
304
8*4.0
1/2.25
18.0
604
19*1.5
1/1.38
20.9
695
3*4
7/0.85
13.1
316
8*4.0
7/0.85
18.9
630
19*1.5
7/0.52
21.8
726
3*6.0
1/2.76
14.1
412
8*6.0
1/2.76
20.0
808
19*2.5
1/1.78
23.3
952
3*6.0
7/1.04
14.9
427
8*6.0
7/1.04
21.2
844
19*2.5
7/0.68
24.6
998
4*1.5
1/1.38
11.5
237
10*1.5
1/1.38
17.5
442
24*1.5
1/1.38
24.7
890
4*1.5
7/0.52
11.9
249
10*1.5
7/0.52
18.2
461
24*1.5
7/0.52
25.8
929
4*2.5
1/1.78
12.4
293
10*2.5
1/1.78
19.1
569
24*2.5
1/1.78
27.1
1183
4*2.5
7/0.68
13.0
305
10*2.5
7/0.68
20.1
596
24*2.5
7/0.68
28.7
1240
4*4.0
1/2.25
14.2
409
10*4.
1/2.25
21.4
779
27*1.5
1/1.38
25.2
976
4*4.0
7/0.85
14.9
425
10*4.0
7/0.85
22.6
813
27*1.5
7/0.52
26.4
1019
4*6.0
1/2.76
15.4
504
10*6.0
1/2.76
23.4
1008
27*2.5
1/1.78
27.7
1303
4*6.0
7/1.04
16.3
523
10*6.0
7/1.04
24.8
1055
27*2.5
7/0.68
29.3
1365
5*1.5
1/1.38
12.4
286
12*1.5
1/1.38
18.0
480
30*1.5
1/1.38
26.1
1065
5*1.5
7/0.52
12.9
295
12*1.5
7/0.52
18.8
501
30*1.5
7/0.52
27.3
1112
5*2.5
1/1.78
14.1
373
12*2.5
1/1.78
19.7
630
30*2.5
1/1.78
28.7
1427
5*2.5
7/0.68
14.8
413
12*2.5
7/0.68
20.7
660
30*2.5
7/0.68
30.4
1496
5*4.0
1/2.25
15.4
490
12*4.0
1/2.25
22.0
865
37*1.5
1/1.38
28.1
1274
5*4.0
7/0.85
16.2
508
12*4.0
7/0.85
23.3
903
37*1.5
7/0.52
29.4
1330
5*6.0
1/2.76
16.8
606
12*6.0
1/2.76
24.1
1135
37*2.5
1/1.78
30.9
1716
5*6.0
7/1.04
17.7
628
12*6.0
7/1.04
25.6
1182
37*2.5
7/0.68
32.8
1798
Table 9 WDZ-YJ(F)Y Irradiation cross-linked polyethylene insulated polyolefin sheathed low-smoke halogen-free flame-retardant power cable
Number of cores*Section mm² Theoretical outer diameter mm Theoretical weight kg/km Number of cores*Section mm² Theoretical outer diameter mm Theoretical weight kg/km
Number of cores*Section mm² Theoretical outer diameter mm Theoretical weight kg/km 1*1.5
5.6
54
3*35
23.4
1361
3*10+1*6
16.4
565
1*2.5
6.0
68
3*50
23.6
1768
3*16+1*10
18.5
807
1*4
6.5
87
3*70
27.0
2393
3*25+1*16
22.3
1225
1*6
7.0
111
3*95
30.1
3147
3*35+1*16
24.1
1529
1*10
8.3
162
3*120
33.5
3932
3*50+1*25
25.9
2063
1*16
9.0
225
3*150
37.3
4919
3*70+1*35
29.9
2806
1*25
10.6
331
3*185
41.3
6044
3*95+1*50
33.8
3744
1*35
11.6
434
3*240
46.7
7771
3*120+1*70
37.4
4734
1*50
13.2
594
4*1.5
10.7
193
3*150+1*70
41.2
5721
1*70
15.1
811
4*2.5
11.7
245
3*185+1*95
46.2
7127
1*95
16.8
1068
4*4
12.8
319
3*240+1*120
51.9
9113
1*120
18.5
1324
4*6
14.0
415
3*300+1*150
57.5
11291
1*150
20.6
1653
4*10
17.2
615
3*2.5+2*1.5
12.2
265
1*185
22.8
2032
4*16
19.0
865
3*4+2*2.5
13.3
343
1*240
25.4
2583
4*25
23.2
1329
3*6+2*4
14.7
453
1*300
30.1
3237
4*35
25.6
1734
3*10+2*6
17.3
651
1*400
33.7
4270
4*50
26.2
2302
3*16+2*10
20.3
948
1*500
38.0
5313
4*70
30.5
3146
3*25+2*16
23.7
1418
1*630
42.1
6658
4*95
34.4
4145
3*35+2*16
25.4
1720
1*800
46.9
8372
4*120
38.0
5200
3*50+2*25
26.2
2317
2*1.5
9.6
130
4*150
42.3
6481
3*70+2*35
30.4
3156
2*2.5
10.4
159
4*185
46.9
7966
3*95+2*50
34.1
4236
2*4
11.3
204
4*240
53.1
10245
3*120+2*70
37.3
5415
2*6
12.3
259
4*300
59.4
12702
3*150+2*70
41.8
6412
2*10
14.9
385
5*1.5
11.5
226
3*185+2*95
46.9
8063
2*16
16.4
514
5*2.5
12.6
290
3*240+2*120
52.7
10273
2*25
20.0
754
5*4
13.9
385
4*2.5+1*1.5
12.4
277
2*35
22.0
965
5*6
15.2
499
4*4+1*2.5
13.6
361
2*50
20.2
1220
5*10
18.7
745
4*6+1*4
15.0
476
2*70
23.0
1642
5*16
20.7
1054
4*10+1*6
18.0
695
2*95
24.8
2132
5*25
25.5
1625
4*16+1*10
20.7
1003
2*120
27.4
2653
5*35
28.4
2144
4*25+1*16
24.6
1522
2*150
30.7
3306
5*50
28.9
2862
4*35+1*16
26.8
1924
2*185
34.2
4080
5*70
33.9
3916
4*50+1*25
26.6
2578
2*240
38.4
5209
5*95
38.1
5178
4*70+1*35
31.1
3540
3*1.5
10.0
162
5*120
41.7
6468
4*95+1*50
34.8
4696
3*2.5
10.8
202
5*150
46.4
8084
4*120+1*70
37.8
5923
3*4
11.9
258
5*185
52.1
9971
4*150+1*70
43.0
7256
3*6
13.0
329
5*240
58.3
12769
4*185+1*95
48.1
9033
3*10
15.7
487
3*2.5+1*1.5
11.4
232
4*240+1*120
54.1
11544
3*16
17.4
678
3*4+1*2.5
12.5
300
3*25
21.2
1053
3*6+1*4
13.7
387
-
Delivery length
The delivery length of the cable should not be less than 100m, and the measurement error should not be greater than 0.5%. According to the agreement between the two parties, delivery of any length is allowed.
Packaging mark and transportation
The cable should be properly packaged on a cable reel for delivery. The length of the cable extension should not be less than 300mm, and the end should be reliably sealed with a cable jacket.
Each cable package should be accompanied by a product quality certificate. The certificate should be placed in an impermeable bag and fixed on the side of the cable reel.
The outside of each cable reel shall be marked:
a. The name or trademark of the manufacturer
b. Cable model and specification
c, length m
d. Date of manufacture: Year Month
e. Standard number
f. Gross weight kg:
g. A symbol indicating the correct direction of rotation of the cable reel
Transport and storage
a. The wire reel is not allowed to lay flat
b. During transportation, it is strictly forbidden to lower the cable reel with cables from a high place, and it is strictly forbidden to lose the cables mechanically.
c. When hoisting packages, it is strictly forbidden to hoist several trays at the same time. On vehicles, ships and other transportation tools, the cable reel must be placed firmly and fixed with a suitable method to prevent mutual collision or overturning.
Previous