1000

BBTRZ

This product is suitable for transmission of electric energy in power lines with a rated voltage of 0.6/1KV and below. It is difficult to catch fire and has the ability to prevent or delay the spread of flames. It is used for laying in a variety of occasions where cables have flame-retardant requirements, such as high-rise buildings, hotels, hospitals, subways, nuclear power plants, power plants, ore, petroleum, and chemical industries. Plastic fire-resistant cable, also known as isolated fire-resistant cable, is a layer of odorless, non-toxic, halogen-free mineral compound material between the insulated core (outer diameter of the cable) and the outer sheath of the cable. When the cable is subjected to a fire, a large amount of crystal water is formed by filling and chromatography. When the flame temperature is lowered, the hydroxide is dehydrated into an infusible and non-combustible inorganic hard shell, which blocks the oxygen supply channel and achieves a high level of fire resistance. .
Number of views:
1000
Quantity
-
+
1
Description
characteristic
process
Standards and specifications
Design and selection
parameter
enclosure
Laying and installation
Application

  Plastic fireproof cable (BBTRZ)
   This product is suitable for power transmission in power lines with a rated voltage of 0.6/1KV and below. Flame-retardant wires and cables are difficult to catch fire and have the ability to prevent or delay the spread of flames. They are used for laying in a variety of occasions where the cable has flame-retardant requirements, such as high-rise buildings, hotels, hospitals, subways, nuclear power plants, power plants, ore, and petroleum. , Chemical industry, etc.
Product implementation standard: GB/T127061-2002.  GB/T183803-2008.  GB/T17651 2-2002.GB/T1 76502-2002.  GB/T1 921 6-2008   
  Instructions for plastic fireproof cable
  Plastic fire-resistant cable is also called isolated fire-resistant cable. It is filled with a layer of odorless, non-toxic, halogen-free mineral compound material between the insulated core (outer diameter of the cable) and the outer sheath of the cable. When the cable is subjected to a fire, a large amount of crystal water is formed by filling and chromatography. When the flame temperature is lowered, the hydroxide is dehydrated into an infusible and non-combustible inorganic hard shell, which blocks the oxygen supply channel and achieves a high level of fire resistance. . 
  Product structure
   plastic fireproof cable is composed of copper stranded wire, cross-linked polyethylene insulation, mineral compound filling and wrapping, and low-smoke halogen-free sheath.
   In addition to meeting the flame-retardant, low-smoke and halogen-free characteristics of low-smoke and halogen-free cables,    plastic fire-resistant cables also meet the requirements of BS6387C, W, and Z laboratory standards.          

 

We could not find any corresponding parameters, please add them to the properties table
Use characteristics 
Rated voltage of the cable U0/U is 0.6/1KV
XLPELong-term allowable working temperature of insulated cable does not exceed 90℃                       
The ambient temperature during installation should not be lower than 0°C.   
Minimum bending radius during cable installation:
 table 3,
Single core cable
Multi-core cable
 project
Unarmored
Armored
Unarmored
Armored
Minimum bending radius during installation
20D
15D
15D
12D

D-the outer diameter of the cable 

 

Main performance

1. The fire resistance of the plastic fireproof cable BBTRZ meets the requirements of BS6387C. W.Z.
Performance comparisonPerformance Comparison
BBTRZ plastic fireproof cable
 Fire-resistant cableFire-resistant Cable
Fire resistance indexFire-resistance index
combustion Combustion
Class A 650℃. 180min
750℃-90min
Class B 750°C.180min
Class C 950℃.180min
Class D 750℃.20min
Spraying
Class W 650℃. 15min
 
Mechanical impact
Class X 650℃.15min
750℃.120min
Class Y 750℃.15min
Class Z 950'℃.15min
2, plastic fireproof cable BBTRZ The flame-retardant properties meet the GB/T18380 flame-retardant Class A standard
3. Plastic fireproof cable BBTRZ The halogen acid gas release test should be able to pass the GB/T17650.1-2002 standard requirements, that is, the total amount of halogen acid gas is determined <5mg/g and GB/T17650.2-2002 is measured by measuring the PH value and conductivity The acidity of the gas (PH in 1L water>=4 3 The conductivity value should not exceed 10us/mrn), the smoke density test should be able to pass the determination of the smoke density of the GB/T17651.2-2002 cable or optical cable burning under specific conditions (transparent The minimum value of the rate≥60%)< /span>
4. Plastic fireproof cable BBTRZ -A should be able to withstand the 3.5KV AC voltage test without breakdown in 5 minutes
5. In addition to the above features In addition, the induced energy should comply with the GB/T12706.1-2002 standard 

Delivery length

The delivery of the cable requires the delivery of the entire cable. In principle, no or fewer connectors are used. When purchasing, specify the construction length requirements (ie delivery length) to the manufacturer.

If a joint is necessary, the fire resistance of the joint should be the same as that of the cable, that is, it must also meet the requirements of BS6387.

Packaging logo and transportation

1. The cable can be packaged in coils or coils. When using reel packaging, the cable should be properly packaged on the cable reel for delivery, the length of the cable extension should not be less than 300mm, and the end should be reliably sealed with a cable jacket.

2. When packaging in a reel, each cable package should be accompanied by a product quality certificate. The certificate should be placed in an impermeable bag and fixed on the side of the cable reel.

The outside of each cable reel should be marked

     a, the name or trademark of the manufacturer i

     b, cable model and specification i

     c, length im

     d, manufacturing date year and month

     e, standard number i

     f, gross weight i kg.

    q, a symbol indicating the correct direction of rotation of the cable reel.

     3. Transportation and storage

     a, the wire reel is not allowed to lay flat i

     b. It is strictly forbidden to drop the cable reel with cables from a high place during transportation, and it is strictly forbidden to damage the cables mechanically.   

  c. It is strictly forbidden to lift several trays at the same time when hoisting packages. On vehicles, ships and other transportation tools, the cable reel must be placed firmly and fixed with a suitable method to prevent mutual collision or overturning.

Representation of plastic fireproof cable products

  The product is expressed by model, rated voltage, core number, nominal cross section and the number of this standard.

  For example:

   rated voltage 600/1000V cross-linked polyethylene insulated low-smoke halogen-free sheathed plastic fireproof power cable 3 cores. 240mm..

Expressed as: BTTRZ-A   600/1000V 3*240    Q/JS12.08-2011.

 

Some cable specifications and reference data

CoreCross-section

( mm )Approximate Outside Diameter (mm)

mm'

1core

2 core 3 core

4 core

5 core

3+1 core

3+2 core

4+1 core

1.5

11.4

14.9

15.8

16.8

17.9

16.5

17.6

17.6

2.5

11.9

15.9

16.7

17.9

18.9

17.6

18.4

18.9

4

12.6

17.3

18.2

19.5

20.8

19.3

19.8

20.9

6

13.2

18.5

19.6

20.8

23.3

20.7

21.9

22.3

10

13.8

20.4

21.5

23.2

25.2

22.8

24.3

24.6

16

15.1

22.6

23.8

25.6

27.8

25.3

26.7

27.6

25

16.5

25.8

27.6

29.8

32.6

28.8

30.9

31.8

35

17.8

28.5

29.6

32.6

36.2

30.9

32.7

34.3

50

19.5

31.6

33.1

36.5

40.6

35.2

37.2

38.7

70

21.4

35.3

37.1

41.4

45.8

39.6

41.5

43.1

95

24.0

41.4

44.1

48.5

53.5

45.2

48.2

51.5

120

26.6

44.7

47.5

52.3

58.1

49.4

52.3

55.4

150

27.6

48.8

52.0

57.4

63.2

53.3

56.4

60.0

185

30.7

53.9

57.6

63.6

70.0

59.7

63.3

66.2

240

33.5

59.7

64.0

71.3

78.1

66.2

70.1

74.8

300

36.5

65.6

70.2

78.2

87.0

73.0

77.0

82.1

 

CoreCross-section

(Kg/Km) Approximate Weight (Kg/Km)

mm'

1 core

2 core

3 core

4 core

5 core

3+1 core

3+2 core

4+1 core

1.5

151

260

284

330

387

312

360

374

2.5

162

295

333

386

460

370

425

444

4

192

354

404

493

592

470

535

565

6

217

430

498

599

734

588

687

700

10

280

535

645

802

980

765

899

923

16

346

687

860

1080

1345

1023

1201

1260

25

470

940

1231

1570

1960

1474

1700

1790

35

581

1170

1530

1989

2488

1765

2034

2235

50

730

1482

1978

2589

3254

2320

2753

2964

70

954

1960

2630

3488

4420

3088

3634

3999

95

1290

2634

3614

4780

6050

4178

4890

5462

120

1560

3190

4399

5830

7370

5200

6151

6750

150

1864

3823

5287

7022

8879

6132

7109

8025

185

2273

4666

6537

8674

11000

7630

9001

9993

240

2870

5920

8350

11160

14200

9800

11487

12820

300

3523

7288

10299

13800

17594

13101

15923

16735

Installation and laying
1. Installation: According to Clause 2.13.10.4 of JGJ16-2008 "Code for Electrical Design of Civil Buildings", BBTRZ cable pair shall be used for the fire-fighting line, and the laying protection measures of the line shall meet the fire-proof requirements
2. Laying:
2.1 The maximum span of the cable should meet the following requirements:
Allowable Span (mm) Allowable Span (mm)

Cable outer diameter

Outside Diameter

Laying Type
Horizontal Horizontal Vertical Vertical
D≤20 400 1000
20 600 1200
30 800 1500
D>50 1000 2500

Laying method
2 2 The cable tray meets the load-bearing capacity of the support and the outer layer of the lossless cable and its core.
2 3 The cable tray should enable the cables to be arranged neatly with each other.
2 4 Parts such as leather goods, cable ties, ropes or supporting parts for fixing cables shall have a smooth surface, easy installation, sufficient mechanical strength and durability suitable for the environment in which they are used.
25 The selection of cable fixing components should meet the following requirements:
Except in the case of AC single-phase power cables, anticorrosive flat steel clamps or nylon cable ties or plastic-plated metal cable ties can be used. Nylon cable ties or plastic-plated metal cable ties should be used in strong corrosive environments.
For the rigid fixing of AC single-phase power cables, aluminum alloys and other clamps that do not constitute a magnetic closed circuit should be used. For other fixing methods, nylon ties or ropes can be used. Do not tie the cables directly with iron wires.