BBTRZ
This product is suitable for transmission of electric energy in power lines with a rated voltage of 0.6/1KV and below. It is difficult to catch fire and has the ability to prevent or delay the spread of flames. It is used for laying in a variety of occasions where cables have flame-retardant requirements, such as high-rise buildings, hotels, hospitals, subways, nuclear power plants, power plants, ore, petroleum, and chemical industries. Plastic fire-resistant cable, also known as isolated fire-resistant cable, is a layer of odorless, non-toxic, halogen-free mineral compound material between the insulated core (outer diameter of the cable) and the outer sheath of the cable. When the cable is subjected to a fire, a large amount of crystal water is formed by filling and chromatography. When the flame temperature is lowered, the hydroxide is dehydrated into an infusible and non-combustible inorganic hard shell, which blocks the oxygen supply channel and achieves a high level of fire resistance. .
Classification:
Key words:
BBTRZ
- Description
- characteristic
- process
- Standards and specifications
- Design and selection
- parameter
- enclosure
- Laying and installation
- Application
-
- Commodity name: BBTRZ
- Commodity ID: 1329827694685868032
This product is suitable for transmission of electric energy in power lines with a rated voltage of 0.6/1KV and below. It is difficult to catch fire and has the ability to prevent or delay the spread of flames. It is used for laying in a variety of occasions where cables have flame-retardant requirements, such as high-rise buildings, hotels, hospitals, subways, nuclear power plants, power plants, ore, petroleum, and chemical industries. Plastic fire-resistant cable, also known as isolated fire-resistant cable, is a layer of odorless, non-toxic, halogen-free mineral compound material between the insulated core (outer diameter of the cable) and the outer sheath of the cable. When the cable is subjected to a fire, a large amount of crystal water is formed by filling and chromatography. When the flame temperature is lowered, the hydroxide is dehydrated into an infusible and non-combustible inorganic hard shell, which blocks the oxygen supply channel and achieves a high level of fire resistance. .
Plastic fireproof cable (BBTRZ)
This product is suitable for power transmission in power lines with a rated voltage of 0.6/1KV and below. Flame-retardant wires and cables are difficult to catch fire and have the ability to prevent or delay the spread of flames. They are used for laying in a variety of occasions where the cable has flame-retardant requirements, such as high-rise buildings, hotels, hospitals, subways, nuclear power plants, power plants, ore, and petroleum. , Chemical industry, etc.
Product implementation standard: GB/T127061-2002. GB/T183803-2008. GB/T17651 2-2002.GB/T1 76502-2002. GB/T1 921 6-2008
Instructions for plastic fireproof cable
Plastic fire-resistant cable is also called isolated fire-resistant cable. It is filled with a layer of odorless, non-toxic, halogen-free mineral compound material between the insulated core (outer diameter of the cable) and the outer sheath of the cable. When the cable is subjected to a fire, a large amount of crystal water is formed by filling and chromatography. When the flame temperature is lowered, the hydroxide is dehydrated into an infusible and non-combustible inorganic hard shell, which blocks the oxygen supply channel and achieves a high level of fire resistance. .
Product structure
plastic fireproof cable is composed of copper stranded wire, cross-linked polyethylene insulation, mineral compound filling and wrapping, and low-smoke halogen-free sheath.
In addition to meeting the flame-retardant, low-smoke and halogen-free characteristics of low-smoke and halogen-free cables, plastic fire-resistant cables also meet the requirements of BS6387C, W, and Z laboratory standards. -
Use characteristicsRated voltage of the cable U0/U is 0.6/1KVXLPELong-term allowable working temperature of insulated cable does not exceed 90℃The ambient temperature during installation should not be lower than 0°C.Minimum bending radius during cable installation:table 3,Single core cableMulti-core cableprojectUnarmoredArmoredUnarmoredArmoredMinimum bending radius during installation20D15D15D12D
D-the outer diameter of the cable
Main performance
1. The fire resistance of the plastic fireproof cable BBTRZ meets the requirements of BS6387C. W.Z.Performance comparisonPerformance ComparisonBBTRZ plastic fireproof cableFire-resistant cableFire-resistant CableFire resistance indexFire-resistance indexcombustion CombustionClass A 650℃. 180min750℃-90minClass B 750°C.180minClass C 950℃.180minClass D 750℃.20minSprayingClass W 650℃. 15minMechanical impactClass X 650℃.15min750℃.120minClass Y 750℃.15minClass Z 950'℃.15min2, plastic fireproof cable BBTRZ The flame-retardant properties meet the GB/T18380 flame-retardant Class A standard3. Plastic fireproof cable BBTRZ The halogen acid gas release test should be able to pass the GB/T17650.1-2002 standard requirements, that is, the total amount of halogen acid gas is determined <5mg/g and GB/T17650.2-2002 is measured by measuring the PH value and conductivity The acidity of the gas (PH in 1L water>=4 3 The conductivity value should not exceed 10us/mrn), the smoke density test should be able to pass the determination of the smoke density of the GB/T17651.2-2002 cable or optical cable burning under specific conditions (transparent The minimum value of the rate≥60%)< /span>4. Plastic fireproof cable BBTRZ -A should be able to withstand the 3.5KV AC voltage test without breakdown in 5 minutes5. In addition to the above features In addition, the induced energy should comply with the GB/T12706.1-2002 standard -
Delivery length
The delivery of the cable requires the delivery of the entire cable. In principle, no or fewer connectors are used. When purchasing, specify the construction length requirements (ie delivery length) to the manufacturer.
If a joint is necessary, the fire resistance of the joint should be the same as that of the cable, that is, it must also meet the requirements of BS6387.
Packaging logo and transportation
1. The cable can be packaged in coils or coils. When using reel packaging, the cable should be properly packaged on the cable reel for delivery, the length of the cable extension should not be less than 300mm, and the end should be reliably sealed with a cable jacket.
2. When packaging in a reel, each cable package should be accompanied by a product quality certificate. The certificate should be placed in an impermeable bag and fixed on the side of the cable reel.
The outside of each cable reel should be marked
a, the name or trademark of the manufacturer i
b, cable model and specification i
c, length im
d, manufacturing date year and month
e, standard number i
f, gross weight i kg.
q, a symbol indicating the correct direction of rotation of the cable reel.
3. Transportation and storage
a, the wire reel is not allowed to lay flat i
b. It is strictly forbidden to drop the cable reel with cables from a high place during transportation, and it is strictly forbidden to damage the cables mechanically.
c. It is strictly forbidden to lift several trays at the same time when hoisting packages. On vehicles, ships and other transportation tools, the cable reel must be placed firmly and fixed with a suitable method to prevent mutual collision or overturning.
-
Representation of plastic fireproof cable products
The product is expressed by model, rated voltage, core number, nominal cross section and the number of this standard.
For example:
rated voltage 600/1000V cross-linked polyethylene insulated low-smoke halogen-free sheathed plastic fireproof power cable 3 cores. 240mm..
Expressed as: BTTRZ-A 600/1000V 3*240 Q/JS12.08-2011.
-
Some cable specifications and reference data
CoreCross-section
( mm )Approximate Outside Diameter (mm)
mm'
1core
2 core 3 core 4 core
5 core
3+1 core
3+2 core
4+1 core
1.5
11.4
14.9
15.8
16.8
17.9
16.5
17.6
17.6
2.5
11.9
15.9
16.7
17.9
18.9
17.6
18.4
18.9
4
12.6
17.3
18.2
19.5
20.8
19.3
19.8
20.9
6
13.2
18.5
19.6
20.8
23.3
20.7
21.9
22.3
10
13.8
20.4
21.5
23.2
25.2
22.8
24.3
24.6
16
15.1
22.6
23.8
25.6
27.8
25.3
26.7
27.6
25
16.5
25.8
27.6
29.8
32.6
28.8
30.9
31.8
35
17.8
28.5
29.6
32.6
36.2
30.9
32.7
34.3
50
19.5
31.6
33.1
36.5
40.6
35.2
37.2
38.7
70
21.4
35.3
37.1
41.4
45.8
39.6
41.5
43.1
95
24.0
41.4
44.1
48.5
53.5
45.2
48.2
51.5
120
26.6
44.7
47.5
52.3
58.1
49.4
52.3
55.4
150
27.6
48.8
52.0
57.4
63.2
53.3
56.4
60.0
185
30.7
53.9
57.6
63.6
70.0
59.7
63.3
66.2
240
33.5
59.7
64.0
71.3
78.1
66.2
70.1
74.8
300
36.5
65.6
70.2
78.2
87.0
73.0
77.0
82.1
CoreCross-section
(Kg/Km) Approximate Weight (Kg/Km)
mm'
1 core
2 core
3 core
4 core
5 core
3+1 core
3+2 core
4+1 core
1.5
151
260
284
330
387
312
360
374
2.5
162
295
333
386
460
370
425
444
4
192
354
404
493
592
470
535
565
6
217
430
498
599
734
588
687
700
10
280
535
645
802
980
765
899
923
16
346
687
860
1080
1345
1023
1201
1260
25
470
940
1231
1570
1960
1474
1700
1790
35
581
1170
1530
1989
2488
1765
2034
2235
50
730
1482
1978
2589
3254
2320
2753
2964
70
954
1960
2630
3488
4420
3088
3634
3999
95
1290
2634
3614
4780
6050
4178
4890
5462
120
1560
3190
4399
5830
7370
5200
6151
6750
150
1864
3823
5287
7022
8879
6132
7109
8025
185
2273
4666
6537
8674
11000
7630
9001
9993
240
2870
5920
8350
11160
14200
9800
11487
12820
300
3523
7288
10299
13800
17594
13101
15923
16735
-
Installation and laying
1. Installation: According to Clause 2.13.10.4 of JGJ16-2008 "Code for Electrical Design of Civil Buildings", BBTRZ cable pair shall be used for the fire-fighting line, and the laying protection measures of the line shall meet the fire-proof requirements
2. Laying:
2.1 The maximum span of the cable should meet the following requirements:
Allowable Span (mm) Allowable Span (mm)Cable outer diameter
Outside Diameter
Laying Type Horizontal Horizontal Vertical Vertical D≤20 400 1000 20 < td=""> <>600 1200 30 < td=""> <>800 1500 D>50 1000 2500 Laying method
2 2 The cable tray meets the load-bearing capacity of the support and the outer layer of the lossless cable and its core.
2 3 The cable tray should enable the cables to be arranged neatly with each other.
2 4 Parts such as leather goods, cable ties, ropes or supporting parts for fixing cables shall have a smooth surface, easy installation, sufficient mechanical strength and durability suitable for the environment in which they are used.
25 The selection of cable fixing components should meet the following requirements:
Except in the case of AC single-phase power cables, anticorrosive flat steel clamps or nylon cable ties or plastic-plated metal cable ties can be used. Nylon cable ties or plastic-plated metal cable ties should be used in strong corrosive environments.
For the rigid fixing of AC single-phase power cables, aluminum alloys and other clamps that do not constitute a magnetic closed circuit should be used. For other fixing methods, nylon ties or ropes can be used. Do not tie the cables directly with iron wires.