Control Cable

This product is suitable for wiring of electrical appliances in power distribution devices with AC rated voltages of 450/750V and below as control, monitoring circuits, protection and measurement. It is suitable for laying in hotels, stations, airports, high-rise buildings, chemicals, petroleum platforms, power stations, subways, tunnels and other fixed laying places.
Number of views:
1000
Quantity
-
+
1
Description
Model and specification
Usage characteristics
Parameter
Transportation

 This product is suitable for the wiring of electrical appliances in power distribution devices with AC rated voltages of 450/750V and below as control, monitoring circuits, protection, and measurement. It is suitable for laying in hotels, stations, airports, high-rise buildings, chemicals, petroleum platforms, power stations, subways, tunnels and other fixed laying places.
Product implementation standard: GB9330-2008
Product structure:

We could not find any corresponding parameters, please add them to the properties table

Table 1 Cable model

Model

Name

manufacturing standard

Main application

KVV

PVC insulated control cable with PVC sheath

GB9330-88

It is applied in places such as indoor, cable trench and pipeline.

KYJV

Crosslinked polyethylene insulated control cable with PVC sheath

Q/TEC16.01-2005

KVV22

PVC insulated control cable with PVC sheath and steel tape armoring

GB9330-88

It is applied in places such as indoor, cable trench and pipeline where there is external mechanical force but without largeforce nbsp; .

KYJV22

Crosslinked polyethylene insulated control cable with PVC sheath and steel tape armoring

Q/TEC16.01-2005

KVVP2

PVC insulated control cable with PVC sheath and copper tape shielding

GB9330-88

It is applied in places such as indoor, cable trench and pipeline where there is shielding requirement

KYJVP2

Crosslinked polyethylene insulated control cable with PVC sheath and copper tape shielding

Q/TEC16.01-2005

KVVP2-22

PVC insulated control cable with PVC sheath, copper tape shielding and steel tape armoring

GB9330-88

It is applied in places such as indoor, cable trench and pipeline where there is relatively large external mechanical reforce .

KYJVP2-22

Crosslinked polyethylene insulated control cable with PVC sheath, copper tape shielding and steel tape armoring

Q/TEC16.01-2005

 

Product specifications:

Table 2 Product Specifications

Model

Nominal cross section

mm2

Core number

KVV

KYJV

1, 1.5, 2.5

2∽61

4, 6

2∽14

10

2∽10

KVV22

KYJV22

1, 1.5, 2.5

7∽61

4, 6

4∽14

10

4∽10

KVVP2

KYJVP2

1, 1.5, 2.5

7∽61

4, 6

4∽14

10

4∽10

KVVP2-22

KYJVP2-22

1, 1.5, 2.5

7∽61

4, 6

4∽14

10

4∽10

Indication method
The product is expressed by model, rated voltage, core number, nominal section and standard number
Example: Copper core XLPE insulated steel tape armored PVC sheathed control cable, rated voltage 450/750V, 7 cores, nominal cross section 1.5mm2,
Expressed as: KYJV22 450/750V 7*1.5 Q/TEC16.01-2005
Insulated core identification
Color identification and number identification are used for the insulated cores
When the insulated cores of cables with 5 cores and below are color-coded, the preferred colors and color sequence are as follows
Two-core cable: no priority color
Three-core cable: green/yellow double color, light blue, brown; or light blue, black, brown
Four-core cable: green/yellow double color, light blue, black, brown; or light blue, black, brown, black or brown
Five-core cable: green/yellow bicolor, light blue, black, brown, black or brown; light blue, black, brown, black or brown
Recognized by numbers, from the inner layer to the outer layer, starting from 1 and arranged in a clockwise direction in the order of natural numbers. The color of the digital sign should be obviously different from that of the insulation. The insulation color is preferably black and the number is white.

Using features
The rated voltage of the cable U0/U is 450/750V
The long-term allowable working temperature of PVC insulated cables does not exceed 70℃
The long-term allowable working temperature of XLPE insulated cable does not exceed 90℃
The ambient temperature during installation should not be lower than 0°C.
The minimum bending radius when the cable is installed: The cable without armor layer should not be less than 6 times the outer diameter of the cable. Cables with armored or copper tape shielding structure should not be less than 12 times the outer diameter of the cable. The flexible cable with shielding layer structure should not be less than 6 times the outer diameter of the cable.
Main performance
The finished cable should withstand AC 3000V, 5min voltage test without breakdown.
The DC resistance of the finished product should meet the requirements of Table 3
The insulated core should be able to withstand the power frequency spark test, the test value is shown in the table below

Nominal insulation thickness mm t≤0.5 0.5 1.0
Spark test voltage KV 4 6 10

The size of the cable structure should meet the requirements of GB9330-88 and Q/TEC16.01-2005

Table 3 Conductor structure

Nominal cross section

mm2

Conductor structure

Min. DC resistance of conductor under temperature 20℃

Conductor type

Diameter

mm

1.0

1

1/1.13

18.1

1.0

2

7/0.43

18.1

1.5

1

1/1.38

12.1

1.5

2

7/0.52

12.1

2.5

1

1/1.78

7.41

2.5

2

7/0.68

7.41

4

1

1/2.25

4.61

4

2

7/0.85

4.61

6

1

1/2.76

3.08

6

2

7/1.04

3.08

10

2

7/1.35

1.83

 

Table 4 Insulation thickness

Nominal cross section

mm2

Nominal thickness of PVC insulation

Nominal thickness of XLPE insulator

1

0.6

0.7

1.5

0.8

0.7

2.5

0.8

0.7

4

0.8

0.7

6

0.8

0.7

10

1.0

0.7

 

Table 5 KVV type 450/750V copper core PVC insulated PVC sheathed control cable

Core number * nominal cross section

mm2

Conductor type

Rated value of sheath thickness

mm

Average overall

diameter

mm

Theoretical weight

Kg/km

Minimum insulation resistance under temperature 70℃

MΩ.km

Core number * nominal cross section

mm2

Conductor type

Rated value of sheath thickness

mm

Average overall diameter

mm

Theoretical weight

Kg/km

Minimum insulation resistance under temperature 70℃

MΩ.km

Lower limit

Upper limit

Lower limit

Upper limit

2*1.0

1

1.2

6.8

8.4

73

0.011

10*1.0

1

1.5

11.5

14.0

238

0.011

2*1.0

2

1.2

6.8

8.8

76

0.013

10*1.0

2

1.5

12.0

15.0

249

0.013

2*1.5

1

1.2

7.6

9.4

92

0.011

10*1.5

1

1.5

13.5

16.0

318

0.011

2*1.5

2

1.2

7.8

10.0

101

0.010

10*1.5

2

1.5

14.0

17.0

332

0.010

2*2.5

1

1.2

8.6

10.5

129

0.010

10*2.5

1

1.5

15.5

18.5

458

0.010

2*2.5

2

1.2

9.0

11.5

135

0.009

10*2.5

2

1.5

16.0

19.5

480

0.009

2*4

1

1.2

9.6

11.5

166

0.0085

10*4.

1

1.7

18.0

20.5

647

0.0085

2*4

2

1.2

10.0

12.5

177

0.0077

10*4.0

2

1.7

18.5

22.5

674

0.0077

2*6

1

1.2

10.5

12.5

216

0.0070

10*6.0

1

1.7

19.5

22.5

865

0.0070

2*6

2

1.2

11.0

14.0

233

0.0065

10*6.0

2

1.7

20.5

25.5

903

0.0065

2*10

2

1.5

14.0

17.5

376

0.0065

10*10

2

1.7

25.5

30.5

1414

0.0065

3*1.0

1

1.2

7.0

8.8

93

0.011

12*1.0

1

1.5

12.0

14.5

265

0.011

3*1.0

2

1.2

7.2

9.2

97

0.013

12*1.0

2

1.5

12.5

15.5

1032

0.013

3*1.5

1

1.2

8.0

9.8

119

0.011

12*1.5

1

1.5

14.0

16.5

359

0.011

3*1.5

2

1.2

8.2

10.5

124

0.010

12*1.5

2

1.5

14.0

17.5

375

0.010

3*2.5

1

1.2

9.2

11.0

167

0.010

12*2.5

1

1.5

16.0

19.0

524

0.010

3*2.5

2

1.2

9.4

12.0

174

0.009

12*2.5

2

1.5

16.5

20.5

548

0.009

3*4

1

1.2

10.0

12.5

219

0.0085

12*4.0

1

1.7

18.5

21.5

743

0.0085

3*4

2

1.2

10.5

13.5

230

0.0077

12*4.0

2

1.7

19.0

23.0

774

0.0077

3*6.0

1

1.5

11.5

14.0

314

0.0070

12*6.0

1

1.7

20.5

23.5

1001

0.0070

3*6.0

2

1.5

12.0

15.0

253

0.0065

12*6.0

2

1.7

21.0

26.0

1039

0.0065

3*10

2

1.5

14.5

18.5

498

0.0065

14*1.0

1

1.5

12.5

15.0

298

0.011

4*1.0

1

1.2

7.6

9.4

111

0.011

14*1.0

2

1.5

13.0

16.0

312

0.013

4*1.0

2

1.2

7.8

10.0

118

0.013

14*1.5

1

1.5

14.5

17.0

407

0.011

4*1.5

1

1.2

8.6

10.5

147

0.011

14*1.5

2

1.5

15.0

18.5

424

0.010

4*1.5

2

1.2

9.0

11.5

153

0.010

14*2.5

1

1.5

17.0

19.5

596

0.010

4*2.5

1

1.2

10.0

12.0

208

0.010

14*2.5

2

1.5

17.5

21.5

624

0.009

4*2.5

2

1.2

10.0

13.0

217

0.009

14*4.0

1

1.7

19.5

22.5

849

0.0085

4*4.0

1

1.5

11.5

14.0

298

0.0085

14*4.0

2

1.7

20.5

24.5

883

0.0077

4*4.0

2

1.5

12.0

15.0

311

0.0077

14*6.0

1

1.7

21.5

24.5

1147

0.0070

4*6.0

1

1.5

12.5

15.0

396

0.0070

14*6.0

2

1.7

22.5

27.0

1190

0.0065

4*6.0

2

1.5

13.0

16.5

412

0.0065

16*1.0

1

1.5

13.0

15.5

332

0.011

4*10

2

1.5

16.0

20.0

633

0.0065

16*1.0

2

1.5

13.5

17.0

348

0.013

5*1.0

1

1.2

8.2

10.0

129

0.011

16*1.5

1

1.5

15.0

18.0

455

0.011

5*1.0

2

1.2

8.4

11.0

135

0.013

16*1.5

2

1.5

15.5

19.5

474

0.010

5*1.5

1

1.2

9.4

11.5

170

0.011

16*2.5

1

1.7

18.0

21.0

690

0.010

5*1.5

2

1.2

9.8

12.5

178

0.010

16*2.5

2

1.7

19.0

23.0

722

0.009

5*2.5

1

1.5

11.5

14.0

267

0.010

19*1.0

1

1.5

14.0

16.5

381

0.011

5*2.5

2

1.5

11.5

14.5

279

0.009

19*1.0

2

1.5

14.5

17.5

398

0.013

5*4.0

1

1.5

12.5

15.0

356

0.0085

19*1.5

1

1.5

16.0

19.0

524

0.011

5*4.0

2

1.5

13.0

16.5

371

0.0077

19*1.5

2

1.5

16.5

20.5

546

0.010

5*6.0

1

1.5

14.0

16.5

472

0.0070

19*2.5

1

1.7

19.0

22.0

798

0.010

5*6.0

2

1.5

14.5

18.0

490

0.0065

19*2.5

2

1.7

20.0

24.0

834

0.009

5*10

2

1.7

18.0

22.5

786

0.0065

24*1.0

1

1.5

16.0

19.0

471

0.011

7*1.0

1

1.2

9.0

11.0

156

0.011

24*1.0

2

1.5

16.5

20.5

492

0.013

7*1.0

2

1.2

9.2

11.5

163

0.013

24*1.5

1

1.7

19.0

22.0

672

0.011

7*1.5

1

1.2

10.0

12.5

211

0.011

24*1.5

2

1.7

20.0

24.0

700

0.010

7*1.5

2

1.2

10.5

13.5

220

0.010

24*2.5

1

1.7

22.5

25.5

993

0.010

7*2.5

1

1.5

12.5

15.0

328

0.010

24*2.5

2

1.7

23.0

28.0

1038

0.009

7*2.5

2

1.5

12.5

16.0

348

0.009

27*1.0

1

1.5

16.5

19.0

516

0.011

7*4.0

1

1.5

13.5

16.5

446

0.0085

27*1.0

2

1.5

17.0

20.5

540

0.013

7*4.0

2

1.5

14.0

17.5

465

0.0077

27*1.5

1

1.7

19.5

22.5

738

0.011

7*6.0

1

1.5

15.0

18.0

598

0.0070

27*1.5

2

1.7

20.0

24.5

769

0.010

7*6.0

2

1.5

15.5

19.5

621

0.0065

27*2.5

1

1.7

23.0

26.0

1096

0.010

7*10

2

1.7

20.0

24.0

996

0.0065

27*2.5

2

1.7

23.5

28.5

1145

0.009

8*1.0

1

1.2

10.0

12.0

177

0.011

30*1.0

1

1.7

17.5

20.5

583

0.011

8*1.0

2

1.2

10.0

13.0

185

0.013

30*1.0

2

1.7

18.0

22.0

610

0.013

8*1.5

1

1.5

12.0

14.5

259

0.011

30*1.5

1

1.7

20.0

23.0

807

0.011

8*1.5

2

1.5

12.5

15.5

270

0.010

30*1.5

2

1.7

21.0

25.0

841

0.010

8*2.5

1

1.5

14.0

16.5

371

0.010

30*2.5

1

1.7

24.0

27.0

1202

0.010

8*2.5

2

1.5

14.0

17.5

389

0.009

30*2.5

2

1.7

24.5

29.5

1256

0.009

8*4.0

1

1.5

15.5

18.0

506

0.0085

37*1.0

1

1.7

18.5

21.5

695

0.011

8*4.0

2

1.5

16.0

19.5

528

0.0077

37*1.0

2

1.7

19.5

23.5

727

0.013

8*6.0

1

1.7

17.5

20.0

699

0.0070

37*1.5

1

1.7

21.5

25.0

967

0.011

8*6.0

2

1.7

18.0

22.0

728

0.0065

37*1.5

2

1.7

22.5

27.0

1007

0.010

8*10

2

1.7

22.5

27.0

1129

0.0065

37*2.5

1

1.7

25.5

29.0

1449

0.010

 

 

 

 

 

 

 

37*2.5

2

1.7

26.5

31.5

1513

0.009

Delivery length
The delivery length of the cable should not be less than 100m, and the measurement error should not be greater than ±0.5%.
24 cores and below: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 5% of the total length of delivery.
More than 24 cores: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 10% of the total length of delivery.
According to the agreement between the two parties, any length of cable is allowed to be delivered.
Packaging signs and transportation
Cables in coils or coils should be neatly wound and properly packaged.
A label should be attached to each circle or plate stating:

Name or trademark of manufacturer
Cable model and specification mm2
Rated voltage V
Length m
Manufacturing Date: Year Month
Standard number
Gross weight kg:
Correct rotation direction of the cable reel
Transport and storage
Spools are not allowed to lay flat
During transportation, it is strictly forbidden to lower the cable reel with cables from a high place, and it is strictly forbidden to lose the cables mechanically.
When hoisting packages, it is strictly forbidden to hoist several trays at the same time. On vehicles, ships and other transportation tools, the cable reel must be placed firmly and fixed with a suitable method to prevent mutual collision or overturning.

Inquiry now

Username used for comment:
MESSAGE
Description:
验证码

Copyright: Jiusheng Electric Co., Ltd   浙ICP备14025988号-1  Powered by www.300.cn

搜索
确认
取消