undefined
+
  • undefined

Control Cable

This product is suitable for wiring of electrical appliances in power distribution devices with AC rated voltages of 450/750V and below as control, monitoring circuits, protection and measurement. It is suitable for laying in hotels, stations, airports, high-rise buildings, chemicals, petroleum platforms, power stations, subways, tunnels and other fixed laying places.

Key words:

Control Cable

Contact Us
  • Description
  • Model and specification
  • Usage characteristics
  • Parameter
  • Transportation
    • Commodity name: Control Cable
    • Commodity ID: 1329827705318428672

    This product is suitable for wiring of electrical appliances in power distribution devices with AC rated voltages of 450/750V and below as control, monitoring circuits, protection and measurement. It is suitable for laying in hotels, stations, airports, high-rise buildings, chemicals, petroleum platforms, power stations, subways, tunnels and other fixed laying places.

     This product is suitable for the wiring of electrical appliances in power distribution devices with AC rated voltages of 450/750V and below as control, monitoring circuits, protection, and measurement. It is suitable for laying in hotels, stations, airports, high-rise buildings, chemicals, petroleum platforms, power stations, subways, tunnels and other fixed laying places.
    Product implementation standard: GB9330-2008
    Product structure:

  • Table 1 Cable model

    Model

    Name

    manufacturing standard

    Main application

    KVV

    PVC insulated control cable with PVC sheath

    GB9330-88

    It is applied in places such as indoor, cable trench and pipeline.

    KYJV

    Crosslinked polyethylene insulated control cable with PVC sheath

    Q/TEC16.01-2005

    KVV22

    PVC insulated control cable with PVC sheath and steel tape armoring

    GB9330-88

    It is applied in places such as indoor, cable trench and pipeline where there is external mechanical force but without largeforce nbsp; .

    KYJV22

    Crosslinked polyethylene insulated control cable with PVC sheath and steel tape armoring

    Q/TEC16.01-2005

    KVVP2

    PVC insulated control cable with PVC sheath and copper tape shielding

    GB9330-88

    It is applied in places such as indoor, cable trench and pipeline where there is shielding requirement

    KYJVP2

    Crosslinked polyethylene insulated control cable with PVC sheath and copper tape shielding

    Q/TEC16.01-2005

    KVVP2-22

    PVC insulated control cable with PVC sheath, copper tape shielding and steel tape armoring

    GB9330-88

    It is applied in places such as indoor, cable trench and pipeline where there is relatively large external mechanical reforce .

    KYJVP2-22

    Crosslinked polyethylene insulated control cable with PVC sheath, copper tape shielding and steel tape armoring

    Q/TEC16.01-2005

     

    Product specifications:

    Table 2 Product Specifications

    Model

    Nominal cross section

    mm2

    Core number

    KVV

    KYJV

    1, 1.5, 2.5

    2∽61

    4, 6

    2∽14

    10

    2∽10

    KVV22

    KYJV22

    1, 1.5, 2.5

    7∽61

    4, 6

    4∽14

    10

    4∽10

    KVVP2

    KYJVP2

    1, 1.5, 2.5

    7∽61

    4, 6

    4∽14

    10

    4∽10

    KVVP2-22

    KYJVP2-22

    1, 1.5, 2.5

    7∽61

    4, 6

    4∽14

    10

    4∽10

    Indication method
    The product is expressed by model, rated voltage, core number, nominal section and standard number
    Example: Copper core XLPE insulated steel tape armored PVC sheathed control cable, rated voltage 450/750V, 7 cores, nominal cross section 1.5mm2,
    Expressed as: KYJV22 450/750V 7*1.5 Q/TEC16.01-2005
    Insulated core identification
    Color identification and number identification are used for the insulated cores
    When the insulated cores of cables with 5 cores and below are color-coded, the preferred colors and color sequence are as follows
    Two-core cable: no priority color
    Three-core cable: green/yellow double color, light blue, brown; or light blue, black, brown
    Four-core cable: green/yellow double color, light blue, black, brown; or light blue, black, brown, black or brown
    Five-core cable: green/yellow bicolor, light blue, black, brown, black or brown; light blue, black, brown, black or brown
    Recognized by numbers, from the inner layer to the outer layer, starting from 1 and arranged in a clockwise direction in the order of natural numbers. The color of the digital sign should be obviously different from that of the insulation. The insulation color is preferably black and the number is white.

  • Using features
    The rated voltage of the cable U0/U is 450/750V
    The long-term allowable working temperature of PVC insulated cables does not exceed 70℃
    The long-term allowable working temperature of XLPE insulated cable does not exceed 90℃
    The ambient temperature during installation should not be lower than 0°C.
    The minimum bending radius when the cable is installed: The cable without armor layer should not be less than 6 times the outer diameter of the cable. Cables with armored or copper tape shielding structure should not be less than 12 times the outer diameter of the cable. The flexible cable with shielding layer structure should not be less than 6 times the outer diameter of the cable.
    Main performance
    The finished cable should withstand AC 3000V, 5min voltage test without breakdown.
    The DC resistance of the finished product should meet the requirements of Table 3
    The insulated core should be able to withstand the power frequency spark test, the test value is shown in the table below

    Nominal insulation thickness mm t≤0.5 0.5< td=""> <> 1.0< td=""> <>
    Spark test voltage KV 4 6 10

    The size of the cable structure should meet the requirements of GB9330-88 and Q/TEC16.01-2005

  • Table 3 Conductor structure

    Nominal cross section

    mm2

    Conductor structure

    Min. DC resistance of conductor under temperature 20℃

    Conductor type

    Diameter

    mm

    1.0

    1

    1/1.13

    18.1

    1.0

    2

    7/0.43

    18.1

    1.5

    1

    1/1.38

    12.1

    1.5

    2

    7/0.52

    12.1

    2.5

    1

    1/1.78

    7.41

    2.5

    2

    7/0.68

    7.41

    4

    1

    1/2.25

    4.61

    4

    2

    7/0.85

    4.61

    6

    1

    1/2.76

    3.08

    6

    2

    7/1.04

    3.08

    10

    2

    7/1.35

    1.83

     

    Table 4 Insulation thickness

    Nominal cross section

    mm2

    Nominal thickness of PVC insulation

    Nominal thickness of XLPE insulator

    1

    0.6

    0.7

    1.5

    0.8

    0.7

    2.5

    0.8

    0.7

    4

    0.8

    0.7

    6

    0.8

    0.7

    10

    1.0

    0.7

     

    Table 5 KVV type 450/750V copper core PVC insulated PVC sheathed control cable

    Core number * nominal cross section

    mm2

    Conductor type

    Rated value of sheath thickness

    mm

    Average overall

    diameter

    mm

    Theoretical weight

    Kg/km

    Minimum insulation resistance under temperature 70℃

    MΩ.km

    Core number * nominal cross section

    mm2

    Conductor type

    Rated value of sheath thickness

    mm

    Average overall diameter

    mm

    Theoretical weight

    Kg/km

    Minimum insulation resistance under temperature 70℃

    MΩ.km

    Lower limit

    Upper limit

    Lower limit

    Upper limit

    2*1.0

    1

    1.2

    6.8

    8.4

    73

    0.011

    10*1.0

    1

    1.5

    11.5

    14.0

    238

    0.011

    2*1.0

    2

    1.2

    6.8

    8.8

    76

    0.013

    10*1.0

    2

    1.5

    12.0

    15.0

    249

    0.013

    2*1.5

    1

    1.2

    7.6

    9.4

    92

    0.011

    10*1.5

    1

    1.5

    13.5

    16.0

    318

    0.011

    2*1.5

    2

    1.2

    7.8

    10.0

    101

    0.010

    10*1.5

    2

    1.5

    14.0

    17.0

    332

    0.010

    2*2.5

    1

    1.2

    8.6

    10.5

    129

    0.010

    10*2.5

    1

    1.5

    15.5

    18.5

    458

    0.010

    2*2.5

    2

    1.2

    9.0

    11.5

    135

    0.009

    10*2.5

    2

    1.5

    16.0

    19.5

    480

    0.009

    2*4

    1

    1.2

    9.6

    11.5

    166

    0.0085

    10*4.

    1

    1.7

    18.0

    20.5

    647

    0.0085

    2*4

    2

    1.2

    10.0

    12.5

    177

    0.0077

    10*4.0

    2

    1.7

    18.5

    22.5

    674

    0.0077

    2*6

    1

    1.2

    10.5

    12.5

    216

    0.0070

    10*6.0

    1

    1.7

    19.5

    22.5

    865

    0.0070

    2*6

    2

    1.2

    11.0

    14.0

    233

    0.0065

    10*6.0

    2

    1.7

    20.5

    25.5

    903

    0.0065

    2*10

    2

    1.5

    14.0

    17.5

    376

    0.0065

    10*10

    2

    1.7

    25.5

    30.5

    1414

    0.0065

    3*1.0

    1

    1.2

    7.0

    8.8

    93

    0.011

    12*1.0

    1

    1.5

    12.0

    14.5

    265

    0.011

    3*1.0

    2

    1.2

    7.2

    9.2

    97

    0.013

    12*1.0

    2

    1.5

    12.5

    15.5

    1032

    0.013

    3*1.5

    1

    1.2

    8.0

    9.8

    119

    0.011

    12*1.5

    1

    1.5

    14.0

    16.5

    359

    0.011

    3*1.5

    2

    1.2

    8.2

    10.5

    124

    0.010

    12*1.5

    2

    1.5

    14.0

    17.5

    375

    0.010

    3*2.5

    1

    1.2

    9.2

    11.0

    167

    0.010

    12*2.5

    1

    1.5

    16.0

    19.0

    524

    0.010

    3*2.5

    2

    1.2

    9.4

    12.0

    174

    0.009

    12*2.5

    2

    1.5

    16.5

    20.5

    548

    0.009

    3*4

    1

    1.2

    10.0

    12.5

    219

    0.0085

    12*4.0

    1

    1.7

    18.5

    21.5

    743

    0.0085

    3*4

    2

    1.2

    10.5

    13.5

    230

    0.0077

    12*4.0

    2

    1.7

    19.0

    23.0

    774

    0.0077

    3*6.0

    1

    1.5

    11.5

    14.0

    314

    0.0070

    12*6.0

    1

    1.7

    20.5

    23.5

    1001

    0.0070

    3*6.0

    2

    1.5

    12.0

    15.0

    253

    0.0065

    12*6.0

    2

    1.7

    21.0

    26.0

    1039

    0.0065

    3*10

    2

    1.5

    14.5

    18.5

    498

    0.0065

    14*1.0

    1

    1.5

    12.5

    15.0

    298

    0.011

    4*1.0

    1

    1.2

    7.6

    9.4

    111

    0.011

    14*1.0

    2

    1.5

    13.0

    16.0

    312

    0.013

    4*1.0

    2

    1.2

    7.8

    10.0

    118

    0.013

    14*1.5

    1

    1.5

    14.5

    17.0

    407

    0.011

    4*1.5

    1

    1.2

    8.6

    10.5

    147

    0.011

    14*1.5

    2

    1.5

    15.0

    18.5

    424

    0.010

    4*1.5

    2

    1.2

    9.0

    11.5

    153

    0.010

    14*2.5

    1

    1.5

    17.0

    19.5

    596

    0.010

    4*2.5

    1

    1.2

    10.0

    12.0

    208

    0.010

    14*2.5

    2

    1.5

    17.5

    21.5

    624

    0.009

    4*2.5

    2

    1.2

    10.0

    13.0

    217

    0.009

    14*4.0

    1

    1.7

    19.5

    22.5

    849

    0.0085

    4*4.0

    1

    1.5

    11.5

    14.0

    298

    0.0085

    14*4.0

    2

    1.7

    20.5

    24.5

    883

    0.0077

    4*4.0

    2

    1.5

    12.0

    15.0

    311

    0.0077

    14*6.0

    1

    1.7

    21.5

    24.5

    1147

    0.0070

    4*6.0

    1

    1.5

    12.5

    15.0

    396

    0.0070

    14*6.0

    2

    1.7

    22.5

    27.0

    1190

    0.0065

    4*6.0

    2

    1.5

    13.0

    16.5

    412

    0.0065

    16*1.0

    1

    1.5

    13.0

    15.5

    332

    0.011

    4*10

    2

    1.5

    16.0

    20.0

    633

    0.0065

    16*1.0

    2

    1.5

    13.5

    17.0

    348

    0.013

    5*1.0

    1

    1.2

    8.2

    10.0

    129

    0.011

    16*1.5

    1

    1.5

    15.0

    18.0

    455

    0.011

    5*1.0

    2

    1.2

    8.4

    11.0

    135

    0.013

    16*1.5

    2

    1.5

    15.5

    19.5

    474

    0.010

    5*1.5

    1

    1.2

    9.4

    11.5

    170

    0.011

    16*2.5

    1

    1.7

    18.0

    21.0

    690

    0.010

    5*1.5

    2

    1.2

    9.8

    12.5

    178

    0.010

    16*2.5

    2

    1.7

    19.0

    23.0

    722

    0.009

    5*2.5

    1

    1.5

    11.5

    14.0

    267

    0.010

    19*1.0

    1

    1.5

    14.0

    16.5

    381

    0.011

    5*2.5

    2

    1.5

    11.5

    14.5

    279

    0.009

    19*1.0

    2

    1.5

    14.5

    17.5

    398

    0.013

    5*4.0

    1

    1.5

    12.5

    15.0

    356

    0.0085

    19*1.5

    1

    1.5

    16.0

    19.0

    524

    0.011

    5*4.0

    2

    1.5

    13.0

    16.5

    371

    0.0077

    19*1.5

    2

    1.5

    16.5

    20.5

    546

    0.010

    5*6.0

    1

    1.5

    14.0

    16.5

    472

    0.0070

    19*2.5

    1

    1.7

    19.0

    22.0

    798

    0.010

    5*6.0

    2

    1.5

    14.5

    18.0

    490

    0.0065

    19*2.5

    2

    1.7

    20.0

    24.0

    834

    0.009

    5*10

    2

    1.7

    18.0

    22.5

    786

    0.0065

    24*1.0

    1

    1.5

    16.0

    19.0

    471

    0.011

    7*1.0

    1

    1.2

    9.0

    11.0

    156

    0.011

    24*1.0

    2

    1.5

    16.5

    20.5

    492

    0.013

    7*1.0

    2

    1.2

    9.2

    11.5

    163

    0.013

    24*1.5

    1

    1.7

    19.0

    22.0

    672

    0.011

    7*1.5

    1

    1.2

    10.0

    12.5

    211

    0.011

    24*1.5

    2

    1.7

    20.0

    24.0

    700

    0.010

    7*1.5

    2

    1.2

    10.5

    13.5

    220

    0.010

    24*2.5

    1

    1.7

    22.5

    25.5

    993

    0.010

    7*2.5

    1

    1.5

    12.5

    15.0

    328

    0.010

    24*2.5

    2

    1.7

    23.0

    28.0

    1038

    0.009

    7*2.5

    2

    1.5

    12.5

    16.0

    348

    0.009

    27*1.0

    1

    1.5

    16.5

    19.0

    516

    0.011

    7*4.0

    1

    1.5

    13.5

    16.5

    446

    0.0085

    27*1.0

    2

    1.5

    17.0

    20.5

    540

    0.013

    7*4.0

    2

    1.5

    14.0

    17.5

    465

    0.0077

    27*1.5

    1

    1.7

    19.5

    22.5

    738

    0.011

    7*6.0

    1

    1.5

    15.0

    18.0

    598

    0.0070

    27*1.5

    2

    1.7

    20.0

    24.5

    769

    0.010

    7*6.0

    2

    1.5

    15.5

    19.5

    621

    0.0065

    27*2.5

    1

    1.7

    23.0

    26.0

    1096

    0.010

    7*10

    2

    1.7

    20.0

    24.0

    996

    0.0065

    27*2.5

    2

    1.7

    23.5

    28.5

    1145

    0.009

    8*1.0

    1

    1.2

    10.0

    12.0

    177

    0.011

    30*1.0

    1

    1.7

    17.5

    20.5

    583

    0.011

    8*1.0

    2

    1.2

    10.0

    13.0

    185

    0.013

    30*1.0

    2

    1.7

    18.0

    22.0

    610

    0.013

    8*1.5

    1

    1.5

    12.0

    14.5

    259

    0.011

    30*1.5

    1

    1.7

    20.0

    23.0

    807

    0.011

    8*1.5

    2

    1.5

    12.5

    15.5

    270

    0.010

    30*1.5

    2

    1.7

    21.0

    25.0

    841

    0.010

    8*2.5

    1

    1.5

    14.0

    16.5

    371

    0.010

    30*2.5

    1

    1.7

    24.0

    27.0

    1202

    0.010

    8*2.5

    2

    1.5

    14.0

    17.5

    389

    0.009

    30*2.5

    2

    1.7

    24.5

    29.5

    1256

    0.009

    8*4.0

    1

    1.5

    15.5

    18.0

    506

    0.0085

    37*1.0

    1

    1.7

    18.5

    21.5

    695

    0.011

    8*4.0

    2

    1.5

    16.0

    19.5

    528

    0.0077

    37*1.0

    2

    1.7

    19.5

    23.5

    727

    0.013

    8*6.0

    1

    1.7

    17.5

    20.0

    699

    0.0070

    37*1.5

    1

    1.7

    21.5

    25.0

    967

    0.011

    8*6.0

    2

    1.7

    18.0

    22.0

    728

    0.0065

    37*1.5

    2

    1.7

    22.5

    27.0

    1007

    0.010

    8*10

    2

    1.7

    22.5

    27.0

    1129

    0.0065

    37*2.5

    1

    1.7

    25.5

    29.0

    1449

    0.010

     

     

     

     

     

     

     

    37*2.5

    2

    1.7

    26.5

    31.5

    1513

    0.009

  • Delivery length
    The delivery length of the cable should not be less than 100m, and the measurement error should not be greater than ±0.5%.
    24 cores and below: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 5% of the total length of delivery.
    More than 24 cores: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 10% of the total length of delivery.
    According to the agreement between the two parties, any length of cable is allowed to be delivered.
    Packaging signs and transportation
    Cables in coils or coils should be neatly wound and properly packaged.
    A label should be attached to each circle or plate stating:

    Name or trademark of manufacturer
    Cable model and specification mm2
    Rated voltage V
    Length m
    Manufacturing Date: Year Month
    Standard number
    Gross weight kg:
    Correct rotation direction of the cable reel
    Transport and storage
    Spools are not allowed to lay flat
    During transportation, it is strictly forbidden to lower the cable reel with cables from a high place, and it is strictly forbidden to lose the cables mechanically.
    When hoisting packages, it is strictly forbidden to hoist several trays at the same time. On vehicles, ships and other transportation tools, the cable reel must be placed firmly and fixed with a suitable method to prevent mutual collision or overturning.


Previous

WRITE A MESSAGE TO US

If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!

Submit Message