Control Cable
This product is suitable for wiring of electrical appliances in power distribution devices with AC rated voltages of 450/750V and below as control, monitoring circuits, protection and measurement. It is suitable for laying in hotels, stations, airports, high-rise buildings, chemicals, petroleum platforms, power stations, subways, tunnels and other fixed laying places.
Classification:
Key words:
Control Cable
- Description
- Model and specification
- Usage characteristics
- Parameter
- Transportation
-
- Commodity name: Control Cable
- Commodity ID: 1329827705318428672
This product is suitable for wiring of electrical appliances in power distribution devices with AC rated voltages of 450/750V and below as control, monitoring circuits, protection and measurement. It is suitable for laying in hotels, stations, airports, high-rise buildings, chemicals, petroleum platforms, power stations, subways, tunnels and other fixed laying places.
This product is suitable for the wiring of electrical appliances in power distribution devices with AC rated voltages of 450/750V and below as control, monitoring circuits, protection, and measurement. It is suitable for laying in hotels, stations, airports, high-rise buildings, chemicals, petroleum platforms, power stations, subways, tunnels and other fixed laying places.
Product implementation standard: GB9330-2008
Product structure: -
Table 1 Cable model
Model
Name
manufacturing standard
Main application
KVV
PVC insulated control cable with PVC sheath
GB9330-88
It is applied in places such as indoor, cable trench and pipeline.
KYJV
Crosslinked polyethylene insulated control cable with PVC sheath
Q/TEC16.01-2005
KVV22
PVC insulated control cable with PVC sheath and steel tape armoring
GB9330-88
It is applied in places such as indoor, cable trench and pipeline where there is external mechanical force but without largeforce nbsp; .
KYJV22
Crosslinked polyethylene insulated control cable with PVC sheath and steel tape armoring
Q/TEC16.01-2005
KVVP2
PVC insulated control cable with PVC sheath and copper tape shielding
GB9330-88
It is applied in places such as indoor, cable trench and pipeline where there is shielding requirement
KYJVP2
Crosslinked polyethylene insulated control cable with PVC sheath and copper tape shielding
Q/TEC16.01-2005
KVVP2-22
PVC insulated control cable with PVC sheath, copper tape shielding and steel tape armoring
GB9330-88
It is applied in places such as indoor, cable trench and pipeline where there is relatively large external mechanical reforce .
KYJVP2-22
Crosslinked polyethylene insulated control cable with PVC sheath, copper tape shielding and steel tape armoring
Q/TEC16.01-2005
Product specifications:
Table 2 Product Specifications
Model
Nominal cross section
mm2
Core number
KVV
KYJV
1, 1.5, 2.5
2∽61
4, 6
2∽14
10
2∽10
KVV22
KYJV22
1, 1.5, 2.5
7∽61
4, 6
4∽14
10
4∽10
KVVP2
KYJVP2
1, 1.5, 2.5
7∽61
4, 6
4∽14
10
4∽10
KVVP2-22
KYJVP2-22
1, 1.5, 2.5
7∽61
4, 6
4∽14
10
4∽10
Indication method
The product is expressed by model, rated voltage, core number, nominal section and standard number
Example: Copper core XLPE insulated steel tape armored PVC sheathed control cable, rated voltage 450/750V, 7 cores, nominal cross section 1.5mm2,
Expressed as: KYJV22 450/750V 7*1.5 Q/TEC16.01-2005
Insulated core identification
Color identification and number identification are used for the insulated cores
When the insulated cores of cables with 5 cores and below are color-coded, the preferred colors and color sequence are as follows
Two-core cable: no priority color
Three-core cable: green/yellow double color, light blue, brown; or light blue, black, brown
Four-core cable: green/yellow double color, light blue, black, brown; or light blue, black, brown, black or brown
Five-core cable: green/yellow bicolor, light blue, black, brown, black or brown; light blue, black, brown, black or brown
Recognized by numbers, from the inner layer to the outer layer, starting from 1 and arranged in a clockwise direction in the order of natural numbers. The color of the digital sign should be obviously different from that of the insulation. The insulation color is preferably black and the number is white. -
Using features
The rated voltage of the cable U0/U is 450/750V
The long-term allowable working temperature of PVC insulated cables does not exceed 70℃
The long-term allowable working temperature of XLPE insulated cable does not exceed 90℃
The ambient temperature during installation should not be lower than 0°C.
The minimum bending radius when the cable is installed: The cable without armor layer should not be less than 6 times the outer diameter of the cable. Cables with armored or copper tape shielding structure should not be less than 12 times the outer diameter of the cable. The flexible cable with shielding layer structure should not be less than 6 times the outer diameter of the cable.
Main performance
The finished cable should withstand AC 3000V, 5min voltage test without breakdown.
The DC resistance of the finished product should meet the requirements of Table 3
The insulated core should be able to withstand the power frequency spark test, the test value is shown in the table belowNominal insulation thickness mm t≤0.5 0.5 < td=""> <>1.0 < td=""> <>Spark test voltage KV 4 6 10 The size of the cable structure should meet the requirements of GB9330-88 and Q/TEC16.01-2005
-
Table 3 Conductor structure
Nominal cross section
mm2
Conductor structure
Min. DC resistance of conductor under temperature 20℃
Conductor type
Diameter
mm
1.0
1
1/1.13
18.1
1.0
2
7/0.43
18.1
1.5
1
1/1.38
12.1
1.5
2
7/0.52
12.1
2.5
1
1/1.78
7.41
2.5
2
7/0.68
7.41
4
1
1/2.25
4.61
4
2
7/0.85
4.61
6
1
1/2.76
3.08
6
2
7/1.04
3.08
10
2
7/1.35
1.83
Table 4 Insulation thickness
Nominal cross section
mm2
Nominal thickness of PVC insulation
Nominal thickness of XLPE insulator
1
0.6
0.7
1.5
0.8
0.7
2.5
0.8
0.7
4
0.8
0.7
6
0.8
0.7
10
1.0
0.7
Table 5 KVV type 450/750V copper core PVC insulated PVC sheathed control cable
Core number * nominal cross section
mm2
Conductor type
Rated value of sheath thickness
mm
Average overall
diameter
mm
Theoretical weight
Kg/km
Minimum insulation resistance under temperature 70℃
MΩ.km
Core number * nominal cross section
mm2
Conductor type
Rated value of sheath thickness
mm
Average overall diameter
mm
Theoretical weight
Kg/km
Minimum insulation resistance under temperature 70℃
MΩ.km
Lower limit
Upper limit
Lower limit
Upper limit
2*1.0
1
1.2
6.8
8.4
73
0.011
10*1.0
1
1.5
11.5
14.0
238
0.011
2*1.0
2
1.2
6.8
8.8
76
0.013
10*1.0
2
1.5
12.0
15.0
249
0.013
2*1.5
1
1.2
7.6
9.4
92
0.011
10*1.5
1
1.5
13.5
16.0
318
0.011
2*1.5
2
1.2
7.8
10.0
101
0.010
10*1.5
2
1.5
14.0
17.0
332
0.010
2*2.5
1
1.2
8.6
10.5
129
0.010
10*2.5
1
1.5
15.5
18.5
458
0.010
2*2.5
2
1.2
9.0
11.5
135
0.009
10*2.5
2
1.5
16.0
19.5
480
0.009
2*4
1
1.2
9.6
11.5
166
0.0085
10*4.
1
1.7
18.0
20.5
647
0.0085
2*4
2
1.2
10.0
12.5
177
0.0077
10*4.0
2
1.7
18.5
22.5
674
0.0077
2*6
1
1.2
10.5
12.5
216
0.0070
10*6.0
1
1.7
19.5
22.5
865
0.0070
2*6
2
1.2
11.0
14.0
233
0.0065
10*6.0
2
1.7
20.5
25.5
903
0.0065
2*10
2
1.5
14.0
17.5
376
0.0065
10*10
2
1.7
25.5
30.5
1414
0.0065
3*1.0
1
1.2
7.0
8.8
93
0.011
12*1.0
1
1.5
12.0
14.5
265
0.011
3*1.0
2
1.2
7.2
9.2
97
0.013
12*1.0
2
1.5
12.5
15.5
1032
0.013
3*1.5
1
1.2
8.0
9.8
119
0.011
12*1.5
1
1.5
14.0
16.5
359
0.011
3*1.5
2
1.2
8.2
10.5
124
0.010
12*1.5
2
1.5
14.0
17.5
375
0.010
3*2.5
1
1.2
9.2
11.0
167
0.010
12*2.5
1
1.5
16.0
19.0
524
0.010
3*2.5
2
1.2
9.4
12.0
174
0.009
12*2.5
2
1.5
16.5
20.5
548
0.009
3*4
1
1.2
10.0
12.5
219
0.0085
12*4.0
1
1.7
18.5
21.5
743
0.0085
3*4
2
1.2
10.5
13.5
230
0.0077
12*4.0
2
1.7
19.0
23.0
774
0.0077
3*6.0
1
1.5
11.5
14.0
314
0.0070
12*6.0
1
1.7
20.5
23.5
1001
0.0070
3*6.0
2
1.5
12.0
15.0
253
0.0065
12*6.0
2
1.7
21.0
26.0
1039
0.0065
3*10
2
1.5
14.5
18.5
498
0.0065
14*1.0
1
1.5
12.5
15.0
298
0.011
4*1.0
1
1.2
7.6
9.4
111
0.011
14*1.0
2
1.5
13.0
16.0
312
0.013
4*1.0
2
1.2
7.8
10.0
118
0.013
14*1.5
1
1.5
14.5
17.0
407
0.011
4*1.5
1
1.2
8.6
10.5
147
0.011
14*1.5
2
1.5
15.0
18.5
424
0.010
4*1.5
2
1.2
9.0
11.5
153
0.010
14*2.5
1
1.5
17.0
19.5
596
0.010
4*2.5
1
1.2
10.0
12.0
208
0.010
14*2.5
2
1.5
17.5
21.5
624
0.009
4*2.5
2
1.2
10.0
13.0
217
0.009
14*4.0
1
1.7
19.5
22.5
849
0.0085
4*4.0
1
1.5
11.5
14.0
298
0.0085
14*4.0
2
1.7
20.5
24.5
883
0.0077
4*4.0
2
1.5
12.0
15.0
311
0.0077
14*6.0
1
1.7
21.5
24.5
1147
0.0070
4*6.0
1
1.5
12.5
15.0
396
0.0070
14*6.0
2
1.7
22.5
27.0
1190
0.0065
4*6.0
2
1.5
13.0
16.5
412
0.0065
16*1.0
1
1.5
13.0
15.5
332
0.011
4*10
2
1.5
16.0
20.0
633
0.0065
16*1.0
2
1.5
13.5
17.0
348
0.013
5*1.0
1
1.2
8.2
10.0
129
0.011
16*1.5
1
1.5
15.0
18.0
455
0.011
5*1.0
2
1.2
8.4
11.0
135
0.013
16*1.5
2
1.5
15.5
19.5
474
0.010
5*1.5
1
1.2
9.4
11.5
170
0.011
16*2.5
1
1.7
18.0
21.0
690
0.010
5*1.5
2
1.2
9.8
12.5
178
0.010
16*2.5
2
1.7
19.0
23.0
722
0.009
5*2.5
1
1.5
11.5
14.0
267
0.010
19*1.0
1
1.5
14.0
16.5
381
0.011
5*2.5
2
1.5
11.5
14.5
279
0.009
19*1.0
2
1.5
14.5
17.5
398
0.013
5*4.0
1
1.5
12.5
15.0
356
0.0085
19*1.5
1
1.5
16.0
19.0
524
0.011
5*4.0
2
1.5
13.0
16.5
371
0.0077
19*1.5
2
1.5
16.5
20.5
546
0.010
5*6.0
1
1.5
14.0
16.5
472
0.0070
19*2.5
1
1.7
19.0
22.0
798
0.010
5*6.0
2
1.5
14.5
18.0
490
0.0065
19*2.5
2
1.7
20.0
24.0
834
0.009
5*10
2
1.7
18.0
22.5
786
0.0065
24*1.0
1
1.5
16.0
19.0
471
0.011
7*1.0
1
1.2
9.0
11.0
156
0.011
24*1.0
2
1.5
16.5
20.5
492
0.013
7*1.0
2
1.2
9.2
11.5
163
0.013
24*1.5
1
1.7
19.0
22.0
672
0.011
7*1.5
1
1.2
10.0
12.5
211
0.011
24*1.5
2
1.7
20.0
24.0
700
0.010
7*1.5
2
1.2
10.5
13.5
220
0.010
24*2.5
1
1.7
22.5
25.5
993
0.010
7*2.5
1
1.5
12.5
15.0
328
0.010
24*2.5
2
1.7
23.0
28.0
1038
0.009
7*2.5
2
1.5
12.5
16.0
348
0.009
27*1.0
1
1.5
16.5
19.0
516
0.011
7*4.0
1
1.5
13.5
16.5
446
0.0085
27*1.0
2
1.5
17.0
20.5
540
0.013
7*4.0
2
1.5
14.0
17.5
465
0.0077
27*1.5
1
1.7
19.5
22.5
738
0.011
7*6.0
1
1.5
15.0
18.0
598
0.0070
27*1.5
2
1.7
20.0
24.5
769
0.010
7*6.0
2
1.5
15.5
19.5
621
0.0065
27*2.5
1
1.7
23.0
26.0
1096
0.010
7*10
2
1.7
20.0
24.0
996
0.0065
27*2.5
2
1.7
23.5
28.5
1145
0.009
8*1.0
1
1.2
10.0
12.0
177
0.011
30*1.0
1
1.7
17.5
20.5
583
0.011
8*1.0
2
1.2
10.0
13.0
185
0.013
30*1.0
2
1.7
18.0
22.0
610
0.013
8*1.5
1
1.5
12.0
14.5
259
0.011
30*1.5
1
1.7
20.0
23.0
807
0.011
8*1.5
2
1.5
12.5
15.5
270
0.010
30*1.5
2
1.7
21.0
25.0
841
0.010
8*2.5
1
1.5
14.0
16.5
371
0.010
30*2.5
1
1.7
24.0
27.0
1202
0.010
8*2.5
2
1.5
14.0
17.5
389
0.009
30*2.5
2
1.7
24.5
29.5
1256
0.009
8*4.0
1
1.5
15.5
18.0
506
0.0085
37*1.0
1
1.7
18.5
21.5
695
0.011
8*4.0
2
1.5
16.0
19.5
528
0.0077
37*1.0
2
1.7
19.5
23.5
727
0.013
8*6.0
1
1.7
17.5
20.0
699
0.0070
37*1.5
1
1.7
21.5
25.0
967
0.011
8*6.0
2
1.7
18.0
22.0
728
0.0065
37*1.5
2
1.7
22.5
27.0
1007
0.010
8*10
2
1.7
22.5
27.0
1129
0.0065
37*2.5
1
1.7
25.5
29.0
1449
0.010
37*2.5
2
1.7
26.5
31.5
1513
0.009
-
Delivery length
The delivery length of the cable should not be less than 100m, and the measurement error should not be greater than ±0.5%.
24 cores and below: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 5% of the total length of delivery.
More than 24 cores: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 10% of the total length of delivery.
According to the agreement between the two parties, any length of cable is allowed to be delivered.
Packaging signs and transportation
Cables in coils or coils should be neatly wound and properly packaged.
A label should be attached to each circle or plate stating:Name or trademark of manufacturer
Cable model and specification mm2
Rated voltage V
Length m
Manufacturing Date: Year Month
Standard number
Gross weight kg:
Correct rotation direction of the cable reel
Transport and storage
Spools are not allowed to lay flat
During transportation, it is strictly forbidden to lower the cable reel with cables from a high place, and it is strictly forbidden to lose the cables mechanically.
When hoisting packages, it is strictly forbidden to hoist several trays at the same time. On vehicles, ships and other transportation tools, the cable reel must be placed firmly and fixed with a suitable method to prevent mutual collision or overturning.
Previous
Next
WRITE A MESSAGE TO US
If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!