Wire

This product is widely used in power transmission and distribution systems and is currently one of the most used products in my country's power grid.
Number of views:
1000
Quantity
-
+
1
Description
Model and specification
Usage characteristics
Parameter
Transportation

Production standard: This product is manufactured according to the GB/T1179 standard.
Scope of application: This product is widely used in power transmission and distribution systems, and is currently one of the most widely used products in my country's power grid.

We could not find any corresponding parameters, please add them to the properties table

Product name and model specifications

First name  Name

Type  Number

Nominal section mm²

Aluminum stranded wire

LJ

16-800

Steel core aluminum stranded wire

LGJ

10/2—630/80

Note: Rare earth aluminum stranded wire and steel core aluminum stranded wire can be produced according to user requirements

First name  Name

Type   Number

Aluminum stranded wire

JL

Steel core aluminum stranded wire

JL/G1A, JL/G1B, JL/G2A, JL/G2B, JL/G3A

Anticorrosive steel core aluminum stranded wire 1)

JL/G1AF, JL/G2AF, JL/G3AF

Aluminum core aluminum stranded wire 2)

JL/LHA1, JL/LHA2

Aluminum clad steel core aluminum stranded wire

JL/LB1A

Note: 1) The coating method of anti-corrosion steel core aluminum stranded wire should be stated when ordering. 2) Individual small specifications are actually mixed twisted wires

Aluminum stranded wire: JL type (LJ type)

Standard call cut face mm²

Structure Number/Diameter mm

Outer diameter mm

Maximum DC resistance Ω/km

Break force kN

Calculate weight kg/km

16

7/1.71

5.13

1.7896

3.04

43.8

25

7/2.13

6.39

1.1453

4.50

68.4

35

7/2.50

7.50

0.8333

6.01

94.0

50

7/3.00

9.00

0.5787

8.41

135.3

70

7/3.60

10.80

0.4019

11.40

194.9

95

7/4.16

12.48

0.3010

15.22

260.2

120

19/2.85

14.25

0.2374

20.61

333.2

150

19/3.15

15.75

0.1943

24.43

407.0

185

19/3.50

17.50

0.1574

30.16

502.4

210

19/3.75

18.75

0.1371

33.58

576.8

240

19/4.00

20.00

0.1205

38.20

656.3

300

37/3.20

22.40

0.0969

49.10

819.8

400

37/3.71

25.97

0.0723

64.00

1102

500

37/4.16

29.12

0.0573

80.46

1385.5

630

61/3.63

32.67

0.0458

100.80

1738.3

800

61/4.09

36.81

0.0361

128.00

2207.4

 

Steel core aluminum stranded wire: JL/G1A type (LGJ type)

Nominal cross-section aluminum/steel mm²

Number of structural elements/diameter mm

Outer diameter mm

Maximum DC resistance Ω/km

Break force kN

Calculate weight kg/km

Aluminum

Steel

10/2

6/1.50

1/1.50

4.50

2.7062

4.14

42.8

16/3

6/1.85

1/1.85

5.55

1.7791

6.13

65.1

25/4

6/2.30

1/2.30

6.90

1.1478

9.13

100.9

35/6

6/2.72

1/2.72

8.16

0.8230

12.55

140.8

50/8

6/3.20

1/3.20

9.60

0.5946

16.81

194.8

50/30

12/2.32

7/2.32

11.60

0.5693

42.61

371.1

70/10

6/3.80

1/3.80

11.40

0.4217

23.36

274.8

70/40

12/2.72

7/2.72

13.60

0.4141

58.22

510.2

95/15

26/2.15

7/1.67

13.61

0.3059

34.93

380.2

95/20

7/4.16

7/1.85

13.87

0.3020

37.24

408.2

95/55

12/3.20

7/3.20

16.00

0.2992

77.85

706.1

120/7

18/2.90

1/2.90

14.50

0.2422

27.74

378.5

120/20

26/2.38

7/1.85

15.07

0.2496

42.2

466.1

120/25

7/4.72

7/2.10

15.74

0.2346

47.96

525.7

120/70

12/3.60

7/3.60

18.00

0.2364

97.92

893.7

150/8

18/3.20

1/3.20

16.00

0.1990

32.73

460.9

150/20

24/2.78

7/1.85

16.67

0.1981

46.78

548.5

150/25

26/2.70

7/2.10

17.10

0.1940

53.67

600.1

150/35

30/2.50

7/2.50

17.50

0.1962

64.94

675.0

185/10

18/3.60

1/3.60

18.00

0.1572

40.51

583.3

185/25

24/3.15

7/2.10

18.90

0.1543

59.23

704.9

185/30

26/2.98

7/2.32

18.88

0.1592

64.56

731.4

185/45

30/2.80

7/2.80

19.60

0.1564

80.54

846.7

210/10

18/3.80

1/3.80

19.00

0.1411

45.14

649.9

210/25

24/3.33

7/2.22

19.98

0.1380

66.19

787.8

210/35

26/3.22

7/2.50

20.38

0.1364

74.11

852.5

210/50

30/2.98

7/2.98

20.86

0.1381

91.23

959.0

240/30

24/3.60

7/2.40

21.60

0.1181

75.19

920.7

240/40

26/3.42

7/2.66

21.66

0.1209

83.76

962.8

240/55

30/3.20

7/3.20

22.40

0.1198

101.74

1105.8

300/15

42/3.00

7/1.67

23.01

0.0973

68.41

938.7

300/20

45/2.93

7/1.95

23.43

0.0952

76.04

1000.8

300/25

48/2.85

7/2.22

23.76

0.0944

83.76

1057.0

300/40

24/3.99

7/2.66

23.94

0.0961

92.36

1131.0

300/50

26/3.83

7/2.98

24.26

0.0964

103.58

1207.7

300/70

30/3.60

7/3.60

25.20

0.0946

127.23

1399.6

400/20

42/3.51

7/1.95

26.91

0.0710

89.48

1284.3

400/25

45/3.33

7/2.22

26.64

0.0737

96.37

1293.5

400/35

48/3.22

7/2.50

26.82

0.0739

103.67

1347.5

400/50

54/3.07

7/3.07

27.63

0.0723

123.04

1510.3

400/65

26/4.42

7/3.44

28.00

0.0724

135.39

1608.7

400/95

30/4.16

19/2.50

29.14

0.0709

171.56

1856.7

500/35

45/3.76

7/2.51

30.1

0.0578

119.41

1650.2

500/45

48/3.60

7/2.80

30.00

0.0591

127.31

1685.5

500/65

54/3.44

7/3.44

30.96

0.0578

153.80

1887.9

630/45

45/4.22

7/2.81

33.8

0.0459

150.45

2079.2

630/55

48/4.12

7/3.20

34.32

0.0452

164.31

2206.4

630/80

54/3.85

19/2.31

34.7

0.0459

191.77

2366.3

Delivery length
The delivery length of the cable should not be less than 100m, and the measurement error should not be greater than ±0.5%.
24 cores and below: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 5% of the total length of delivery.
More than 24 cores: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 10% of the total length of delivery.
According to the agreement between the two parties, any length of cable is allowed to be delivered.
Packaging signs and transportation 
Cables in coils or coils should be neatly wound and properly packaged.
Each circle or plate should be attached with a label indicating:
Manufacturer name or trademark
Cable model and specification mm2
Rated voltage V
Length m
Manufacturing Date: Year Month
Standard number
Gross weight kg:
Correct rotation direction of the cable reel
Transport and storage
Spools are not allowed to lay flat
During transportation, it is strictly forbidden to lower the cable reel with cables from a high place, and it is strictly forbidden to lose the cables mechanically.
When hoisting packages, it is strictly forbidden to hoist several trays at the same time. On vehicles, ships and other transportation tools, the cable reel must be placed firmly and fixed with a suitable method to prevent mutual collision or overturning.

Next

Inquiry now

Username used for comment:
MESSAGE
Description:
验证码

Copyright: Jiusheng Electric Co., Ltd   浙ICP备14025988号-1  Powered by www.300.cn

搜索
确认
取消