PRODUCTS
We will wholeheartedly provide new and old customers at home and abroad with high-quality products, preferential prices and excellent services
1/1
Number of views:
1000

Overhead cable

The product is weather-resistant cross-linked polyethylene, weather-resistant high-density polyethylene or weather-resistant polyvinyl chloride extruded outside of compacted copper and aluminum conductors. Its structure is simple, safe and reliable. At the same time, it has excellent mechanical and physical properties and electrical properties. Resistance to electrical tracking, creeping discharge resistance, and excellent atmospheric resistance. Compared with bare wires, the laying gap is small, the line corridor is saved, and the line voltage drop is reduced. Especially to reduce power supply accidents and ensure personal safety, it is suitable for cities, rural areas, mountainous areas, forest areas, and mining areas. It is an all-weather cable product.
Number of views:
1000
Quantity
-
+
1
Description
Model and specification
Usage characteristics
Parameter
Transportation

Standard
     This product is produced according to GB/T12527 "Overhead insulated cables with rated voltage of 1kV and below" and GB/T14049 "Overhead insulated cables with rated voltage of 10kV".
Features and uses
     The product is weather-resistant cross-linked polyethylene, weather-resistant high-density polyethylene or weather-resistant PVC extruded outside of compacted copper and aluminum conductors. Its structure is simple, safe and reliable. At the same time, it has excellent mechanical and physical properties and electrical properties. Resistance to electrical tracking, creeping discharge resistance, and excellent atmospheric resistance. Compared with bare wires, the laying gap is small, the line corridor is saved, and the line voltage drop is reduced. Especially to reduce power supply accidents and ensure personal safety, it is suitable for cities, rural areas, mountainous areas, forest areas, and mining areas. It is an all-weather cable product.

We could not find any corresponding parameters, please add them to the properties table

Model

Rated voltage kV

Model

Name

Main purpose

1

JKV

JKLV

Copper core PVC insulated overhead cable with rated voltage of 1kV

Aluminum core PVC insulated overhead cable with rated voltage of 1kV

Overhead fixed laying of lead-in wires, etc.

JKY

JKLY

Copper core polyethylene insulated overhead cable with rated voltage of 1kV

Aluminum core polyethylene insulated overhead cable with rated voltage of 1kV

Overhead fixed laying of lead-in wires, etc.

JKYJ

JKLYJ

Copper core XLPE insulated overhead cable with rated voltage of 1kV

Aluminum core XLPE insulated overhead cable with rated voltage of 1kV

Overhead fixed laying of lead-in wires, etc.

10

JKYJ

JKLYJ

JKTRYJ

Copper core XLPE insulated aerial cable

Aluminum core XLPE insulated aerial cable

Soft copper core XLPE insulated aerial cable

When overhead fixed laying and cable erection, a certain distance between the cable and the tree should be considered. When the cable is running, frequent contact between the cable and the tree is allowed

10

kV

Aluminum core lightweight XLPE thin insulated aerial cable

When overhead fixed laying and cable erection, a certain distance between the cable and the tree should be considered. When the cable is running, only short-term contact between the cable and the tree is allowed

Specifications

Rated voltage kV

Number of cores

Nominal cross section㎜2

10

1, 3, 3+K

25-300

1

1, 2, 3, 4

16-300

Using features

1. There are two types of cable rated voltages
a.1kV,    b.10kV
2. Long-term allowable working temperature of the cable
Polyvinyl chloride insulation is 70℃
High-density polyethylene insulation is 70℃
XLPE insulation is 90℃
3. When short circuit (the longest duration does not exceed 5 seconds), the maximum temperature of the cable
PVC insulation is 160℃
High-density polyethylene insulation is 150℃
XLPE insulation is 250℃
4. The laying temperature of the cable should not be lower than -20℃
5. Allowable bending radius of the cable
Cables with rated voltage of 1kV and below:
For cable outer diameter D<25mm, the bending radius is not less than 4D
Cable outer diameter D≥25㎜, the bending radius is not less than 6D
Rated voltage 10kV cable
Single core cable: 20(d+D)±5%
Multi-core cable: 15(d+D)±5%
D-The actual outer diameter of the cable (mm),
d-The actual outer diameter of the conductor (mm).

1kV single core PVC insulated overhead cable  JKV, JKLV

Nominal section mm²

Insulation thickness mm

Theoretical cable outer diameter mm

Theoretical cable weight kg/km

Maximum conductor resistance at 20℃  Ω/km

Cable breaking force N

Cu

AL

Hard copper

AL

Hard copper

AL

16

1.2

7.2

177 

78

1.198

1.91

5486

2517

25

1.2

8.4

264

110

0.749

1.20

8465

3762

35

1.4

9.8

369

152

0.540

0.868

11731

5177

50

1.4

11.1

511

201

0.399

0.641

16502

7011

70

1.4

12.8

700

267

0.276

0.443

23461

10354

95

1.6

14.8

948

360

0.199

0.320

31759

13727

120

1.6

16.2

1181

438

0.158

0.253

39911

17339

150

1.8

18.2

1478

550

0.128

0.206

49505

21033

185

2.0

20.2

1823

678

0.1021

0.164

61846

26732

240

2.2

22.8

2356

870

0.0777

0.125

79823

34679

300

2.2

25.4

2938

1081

0.0619

0.100

99788

43349

 

1kV single core XLPE insulated aerial cable  JKYJ, JKLYJ

Nominal section mm²

Insulation thickness mm

Theoretical cable outer diameter mm

Theoretical cable weight kg/km

Maximum DC resistance of conductor  Ω/km

Cable breaking force N

Cu

AL

Hard copper

AL

Hard copper

AL

16

1.2

7.2

167

68

1.198

1.91

5486

2517

25

1.2

8.4

252

97

0.749

1.20

8465

3762

35

1.4

9.8

351

135

0.540

0.868

11731

5177

50

1.4

11.1

491

181

0.399

0.641

16502

7011

70

1.4

12.8

677

244 

0.276

0.443

23461

10354

95

1.6

14.8

917

329

0.199

0.320

31759

13727

120

1.6

16.2

1147

404

0.158

0.253

39911

17339

150

1.8

18.2

1435

506

0.128

0.206

49505

21033

185

2.0

20.2

1769

624

0.1021

0.164

61846

26732

240

2.2

22.8

2289

803

0.0777

0.125

79823

34679

300

2.4

25.4

2856

999

0.0619

0.100

99788

43349

 

10kV single core XLPE insulated aerial cable  JKYJ, JKLYJ

Nominal section mm²

Insulation thickness mm

Theoretical cable outer diameter mm

Theoretical cable weight kg/km

Maximum DC resistance of conductor  Ω/km

Cable breaking force N

Cu

AL

Soft copper

Hard copper

AL

Hard copper core

Aluminum core

25

3.4

13.8

351

196

0.727

0.749

1.20

8465

3762

35

3.4

14.8

453

236.

0.524

0.540

0.868

11731

5177

50

3.4

16.1

603

293

0.387

0.399

0.641

16502

7011

70

3.4

17.8

803

369

0.268

0.276

0.443

23461

10354

95

3.4

19.6

1053

465

0.193

0.199

0.320

31759

13727

120

3.4

21.0

1293

551

0.153

0.158

0.253

39911

17339

150

3.4

22.6

1581

653

0.124

0.128

0.206

49505

21033

185

3.4

24.2

1914

769

0.0991

0.1021

0.164

61846

26732

240

3.4

26.4

2432

946

0.0754

0.0777

0.125

79823

34679

300

3.4

28.6

2994

1137

0.0601

0.0619

0.100

99788

43349

 

10kV single-core XLPE insulated light-duty (thin insulated) aerial cable JKYJ/Q JKLYJ/Q

Nominal section mm²

Insulation thickness mm

Theoretical cable outer diameter mm

Theoretical cable weight kg/km

Maximum DC resistance of conductor  Ω/km

Cable breaking force N

Cu

AL

Cu

AL

Cu

AL

25

2.5

11.0

292

137

0.749

1.200

8465

3762

35

2.5

12.0

389

172

0.540

0.868

11731

5177

50

2.5

13.3

533

223

0.399

0.641

16502

7011

70

2.5

15.0

724

291

0.276

0.443

23461

10354

95

2.5

16.6

960

372

0.199

0.320

31759

13727

120

2.5

18.0

1193

450

0.158

0.253

39911

17339

150

2.5

19.6

1473

544

0.128

0.206

49505

21033

185

2.5

21.2

1797

652

0.1021

0.164

61846

26732

240

2.5

23.4

2304

818

0.0777

0.125

79823

34679

300

2.5

25.6

2855

998

0.0619

0.100

99788

43349

Delivery length 
The delivery length of the cable should not be less than 100m, and the measurement error should not be greater than ±0.5%.
24 cores and below: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 5% of the total length of delivery.
More than 24 cores: It is allowed to deliver short cables with a length of not less than 20 meters, and the quantity should not exceed 10% of the total length of delivery.
According to the agreement between the two parties, any length of cable is allowed to be delivered.


Packaging signs and transportation
Cables in coils or coils should be neatly wound and properly packaged.
Each circle or plate should be attached with a label indicating:
Manufacturer name or trademark
Cable model and specification mm2
Rated voltage V
Length m
Manufacturing Date: Year Month
Standard number
Gross weight kg:
Correct rotation direction of the cable reel
Transport and storage
Spools are not allowed to lay flat
During transportation, it is strictly forbidden to lower the cable reel with cables from a high place, and it is strictly forbidden to lose the cables mechanically.
When hoisting packages, it is strictly forbidden to hoist several trays at the same time. On vehicles, ships and other transportation tools, the cable reel must be placed firmly and fixed with a suitable method to prevent mutual collision or overturning.

Inquiry now

Username used for comment:
MESSAGE
Description:
验证码

Copyright: Jiusheng Electric Co., Ltd   浙ICP备14025988号-1  Powered by www.300.cn

搜索
确认
取消